İnşaat Mühendisliği Bölümü Yayın Koleksiyonu
Permanent URI for this collectionhttps://hdl.handle.net/20.500.12416/395
Browse
2 results
Search Results
Conference Object Examination of code performance limits for shear walls(2012) Kazaz, İ.; Gülkan, Polat; Yakut, A.Recently proposed changes to modeling and acceptance criteria in seismic regulations for both flexure and shear dominated reinforced concrete structural walls suggest that a comprehensive examination is required for improved limit state definitions and their corresponding values. This study utilizes a well calibrated modeling tool to investigate the deformation measures defined in terms of plastic rotations and local concrete and steel strains at the extreme fiber of rectangular structural walls. We compare requirements in ASCE/SEI 41, Eurocode 8 and the Turkish Seismic Code. This way, a critical evaluation of the requirements embedded in these documents becomes possible. It is concluded that the performance limits must be refined by introducing additional parameters. Significant recommendations are provided for Eurocode 8 and the Turkish Seismic Code.Article Citation - WoS: 8Citation - Scopus: 9Dynamic Shear Force Amplification in Regular Frame-Wall Systems(Wiley-blackwell, 2016) Kazaz, Ilker; Gulkan, PolatA parametric study is conducted to investigate the dynamic shear amplification factor (DAF) in low-to-mid-rise frame-wall systems in which the reinforcement curtailment along the height matches the required code strength. The level of frame-wall interaction is varied by changing the wall index, defined as the ratio of the total wall area to the floor plan area, in a generic frame-wall system, and its correlation with the DAF is investigated. Wall index values ranging in the 0.2% to 2% interval are selected. Walls with lengths of 3m, 5m and 8m are used in the design of model buildings of 4, 8 and 12 stories. Shear-flexure beam continuum formulation is used in design and modeling. The global behavior is analyzed using nonlinear response history procedure using spectrum compatible ground motions. It is found that the primary source of amplification is the level of inelastic demand on the system. Walls designed for code-specified force reduction factor R=6 experienced an average base shear force amplification in the order of 1.64 with standard deviation of 0.19 with respect to design shear force. Amplification diminishes with decreasing R. An expression for the dynamic amplification factor as a function of the number of stories and force reduction factor R is proposed. Copyright (C) 2015 John Wiley & Sons, Ltd.
