Numerical study on effects of computational domain length on flow field in standing wave thermoacoustic couple

dc.authorid Yildirim, Ender/0000-0002-7969-2243
dc.authorscopusid 57206666390
dc.authorscopusid 36165070100
dc.authorscopusid 6701516974
dc.authorwosid Turkoglu, Hasmet/Jjd-2788-2023
dc.authorwosid Yıldırım, Ender/K-3962-2019
dc.contributor.author Mergen, Suhan
dc.contributor.author Yildirim, Ender
dc.contributor.author Turkoglu, Hasmet
dc.contributor.other Makine Mühendisliği
dc.date.accessioned 2020-02-26T13:13:29Z
dc.date.available 2020-02-26T13:13:29Z
dc.date.issued 2019
dc.department Çankaya University en_US
dc.department-temp [Mergen, Suhan; Yildirim, Ender; Turkoglu, Hasmet] Gazi Univ, Mech Engn Dept, Ankara, Turkey; [Mergen, Suhan] Cankaya Univ, Mech Engn Dept, Ankara, Turkey en_US
dc.description Yildirim, Ender/0000-0002-7969-2243 en_US
dc.description.abstract For the analysis of thermoacoustic (TA) devices, computational methods are commonly used. In the computational studies found in the literature, the flow domain has been modelled differently by different researchers. A common approach in modelling the flow domain is to truncate the computational domain around the stack, instead of modelling the whole resonator to save computational time. However, where to truncate the domain is not clear. In this study, we have investigated how the simulation results are affected by the computational domain length (I-d) when the truncated domain approach is used. For this purpose, a standing wave TA couple which undergoes a refrigeration cycle was considered. The stack plate thickness was assumed to be zero and the simulations were performed for six different dimensionless domain length (I-d/lambda) varying between 0.029 and 0.180. Frequency and Mach number were taken as 100 Hz and 0.01, respectively, and kept constant for all the cases considered. The mean pressure and the pressure amplitude were taken as 10 kPa and 170 Pa, respectively (Drive ratio of 1.7%). Helium was considered as the working fluid. To assess the accuracy of the simulation results, the pressure distributions across the domain were compared with that of the standing wave. In addition to the pressure variation, the effects of the domain length on the phase delay of the pressure and velocity waves along the stack plate were also investigated. The results showed that with the increasing I-d/lambda. ratio, the simulated pressure distribution compares better with the standing wave pressure distribution. With the lowest I-d/lambda ratio (0.029) considered, the difference between the amplitudes of the computed pressure distribution and theoretical standing wave pressure distribution was approximately 50 Pa. However, as I-d/lambda value increases, the simulation results approach to the theoretical standing wave pressure distribution better. The computational results obtained with Id/lambda = 0.132 and 0.180, were almost identical with standing wave acoustic field. Hence, it was concluded that the domain length has a significant effect on the accuracy of the computational results when the truncated domain approach is used. It was also observed that for a given TA device and operating parameters, there is a minimum I-d/lambda value for obtaining reliable results. en_US
dc.description.publishedMonth 3
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.citation Mergen, Suhan; Yildirim, Ender; Turkoglu, Hasmet, "Numerical study on effects of computational domain length on flow field in standing wave thermoacoustic couple", Cryogenics, Vol. 98, pp. 139-147, (2019). en_US
dc.identifier.doi 10.1016/j.cryogenics.2018.09.012
dc.identifier.endpage 147 en_US
dc.identifier.issn 0011-2275
dc.identifier.issn 1879-2235
dc.identifier.scopus 2-s2.0-85061794584
dc.identifier.scopusquality Q3
dc.identifier.startpage 139 en_US
dc.identifier.uri https://doi.org/10.1016/j.cryogenics.2018.09.012
dc.identifier.volume 98 en_US
dc.identifier.wos WOS:000461531200018
dc.identifier.wosquality Q3
dc.institutionauthor Yıldırım, Ender
dc.institutionauthor Türkoğlu, Haşmet
dc.language.iso en en_US
dc.publisher Elsevier Sci Ltd en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 14
dc.subject Standing Wave en_US
dc.subject Thermoacoustic en_US
dc.subject Refrigerator en_US
dc.title Numerical study on effects of computational domain length on flow field in standing wave thermoacoustic couple tr_TR
dc.title Numerical Study on Effects of Computational Domain Length on Flow Field in Standing Wave Thermoacoustic Couple en_US
dc.type Article en_US
dc.wos.citedbyCount 11
dspace.entity.type Publication
relation.isAuthorOfPublication 8f09d499-bbdb-4f2a-8fd5-9a2e648a5eac
relation.isAuthorOfPublication 05bb7e0d-de81-461a-81fe-d9edc5169945
relation.isAuthorOfPublication.latestForDiscovery 8f09d499-bbdb-4f2a-8fd5-9a2e648a5eac
relation.isOrgUnitOfPublication b3982d12-14ba-4f93-ae05-1abca7e3e557
relation.isOrgUnitOfPublication.latestForDiscovery b3982d12-14ba-4f93-ae05-1abca7e3e557

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: