Non-Linear Eddy Current Loss and Thermal Analysis on Transformer Cover

dc.authorscopusid 57206234099
dc.authorscopusid 15019302900
dc.authorwosid Zahedi, Mohammad Zia/Hja-0803-2022
dc.authorwosid Iskender, Ires/Aak-8084-2020
dc.contributor.author Zahedi, Mohammad Zia
dc.contributor.author İskender, İres
dc.contributor.author Iskender, Ires
dc.contributor.authorID 133746 tr_TR
dc.contributor.other Elektrik-Elektronik Mühendisliği
dc.date.accessioned 2020-03-06T12:19:59Z
dc.date.available 2020-03-06T12:19:59Z
dc.date.issued 2019
dc.department Çankaya University en_US
dc.department-temp [Zahedi, Mohammad Zia] Gazi Univ, Engn Fac, Elect & Elect Dept, Ankara, Turkey; [Zahedi, Mohammad Zia] Kabul Polytech Univ, Electromechan Fac, Phys Dept, Kabul, Afghanistan; [Iskender, Ires] Cankaya Univ, Engn Fac, Elect & Elect Dept, Ankara, Turkey en_US
dc.description.abstract High current conductors of transformers cause to produce losses and thermal problems in their tank cover. Finite Difference (FD) Method (FDM) magnetic analysis is used to find out an exact estimation of the magnetic field and the losses near the bushings in the transient solution, considering the non-linear magnetic permeability of the cover plate, because FDM is more flexible to deal with the nonlinear constitutive law and easy-to-be implemented especially in the case of simple geometry. Finite Element Method (FEM) thermal analysis is used to determine the plate temperature based on magnetic FD analysis, taking account non-linear heat flux boundary condition. A calibration procedure is used between the analyses to ensure the precision of assumptions. The reliability of the technique, confirmed by experimental and FEM results. en_US
dc.description.woscitationindex Emerging Sources Citation Index
dc.identifier.citation Zahedi, Mohammad Zia; Iskender, Ires, "Non-Linear Eddy Current Loss and Thermal Analysis on Transformer Cover", Gazi University Journal of Sience, Vol. 32, No. 2, pp. 558-570, (2019). en_US
dc.identifier.endpage 570 en_US
dc.identifier.issn 2147-1762
dc.identifier.issue 2 en_US
dc.identifier.scopus 2-s2.0-85073767702
dc.identifier.scopusquality Q3
dc.identifier.startpage 558 en_US
dc.identifier.volume 32 en_US
dc.identifier.wos WOS:000471792600013
dc.identifier.wosquality N/A
dc.language.iso en en_US
dc.publisher Gazi Univ en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 0
dc.subject Eddy Current Losses en_US
dc.subject Finite Difference Method en_US
dc.subject Finite Element Simulation en_US
dc.subject Hot Spot Temperature en_US
dc.subject Transformer Cover en_US
dc.title Non-Linear Eddy Current Loss and Thermal Analysis on Transformer Cover tr_TR
dc.title Non-Linear Eddy Current Loss and Thermal Analysis on Transformer Cover en_US
dc.type Article en_US
dc.wos.citedbyCount 0
dspace.entity.type Publication
relation.isAuthorOfPublication 2219cbd5-9b30-48e0-b360-4bc56c99320f
relation.isAuthorOfPublication.latestForDiscovery 2219cbd5-9b30-48e0-b360-4bc56c99320f
relation.isOrgUnitOfPublication a8b0a996-7c01-41a1-85be-843ba585ef45
relation.isOrgUnitOfPublication.latestForDiscovery a8b0a996-7c01-41a1-85be-843ba585ef45

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: