Experimental investigation of flow and heat transfer in rectangular cross-sectioned duct with baffles mounted on the bottom surface with different inclination angles
dc.authorid | Arslan, Kamil/0000-0002-1216-6812 | |
dc.authorscopusid | 24478639200 | |
dc.authorscopusid | 6602850643 | |
dc.authorwosid | Arslan, Kamil/N-6684-2019 | |
dc.contributor.author | Arslan, Kamil | |
dc.contributor.author | Onur, Nevzat | |
dc.contributor.author | Onur, Nevzat | |
dc.contributor.authorID | 47465 | tr_TR |
dc.contributor.authorID | 53858 | tr_TR |
dc.contributor.other | Makine Mühendisliği | |
dc.date.accessioned | 2017-06-09T11:59:05Z | |
dc.date.available | 2017-06-09T11:59:05Z | |
dc.date.issued | 2014 | |
dc.department | Çankaya University | en_US |
dc.department-temp | [Arslan, Kamil] Cankiri Karatekin Univ, Tech & Business Coll, TR-18200 Tasmescit, Cankiri, Turkey; [Onur, Nevzat] Cankaya Univ, Fac Engn, Dept Mech Engn, TR-06810 Ankara, Turkey | en_US |
dc.description | Arslan, Kamil/0000-0002-1216-6812 | en_US |
dc.description.abstract | In this study, steady-state forced convection heat transfer and pressure drop characteristics in a horizontal rectangular cross-sectioned duct, baffles mounted on the bottom surface with different inclination angles were investigated experimentally in the Reynolds number range from 1 x 10(3) to 1 x 10(4). The study was performed under turbulent flow conditions. Effects of different baffle inclination angles on flow and heat transfer were studied. Results are also presented in terms of thermal enhancement factor. It is observed that increasing in baffle inclination angle enhances the heat transfer and causes an increase in pressure drop in the duct. | en_US |
dc.description.publishedMonth | 2 | |
dc.description.sponsorship | Unit of Scientific Research Projects of Gazi University | en_US |
dc.description.sponsorship | The authors wish to thank the Unit of Scientific Research Projects of Gazi University for financial support of this project. | en_US |
dc.description.woscitationindex | Science Citation Index Expanded | |
dc.identifier.citation | Arslan, K., Onur, N. (2014). Experimental investigation of flow and heat transfer in rectangular cross-sectioned duct with baffles mounted on the bottom surface with different inclination angles. Heat And Mass Transfer, 50(2), 169-181. http://dx.doi.org/10.1007/s00231-013-1236-6 | en_US |
dc.identifier.doi | 10.1007/s00231-013-1236-6 | |
dc.identifier.endpage | 181 | en_US |
dc.identifier.issn | 0947-7411 | |
dc.identifier.issn | 1432-1181 | |
dc.identifier.issue | 2 | en_US |
dc.identifier.scopus | 2-s2.0-84893727843 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 169 | en_US |
dc.identifier.uri | https://doi.org/10.1007/s00231-013-1236-6 | |
dc.identifier.volume | 50 | en_US |
dc.identifier.wos | WOS:000330342300003 | |
dc.identifier.wosquality | Q3 | |
dc.language.iso | en | en_US |
dc.publisher | Springer | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.scopus.citedbyCount | 18 | |
dc.title | Experimental investigation of flow and heat transfer in rectangular cross-sectioned duct with baffles mounted on the bottom surface with different inclination angles | tr_TR |
dc.title | Experimental Investigation of Flow and Heat Transfer in Rectangular Cross-Sectioned Duct With Baffles Mounted on the Bottom Surface With Different Inclination Angles | en_US |
dc.type | Article | en_US |
dc.wos.citedbyCount | 15 | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 394b9301-2fa4-4d79-b7e9-5203bbc124a2 | |
relation.isAuthorOfPublication.latestForDiscovery | 394b9301-2fa4-4d79-b7e9-5203bbc124a2 | |
relation.isOrgUnitOfPublication | b3982d12-14ba-4f93-ae05-1abca7e3e557 | |
relation.isOrgUnitOfPublication.latestForDiscovery | b3982d12-14ba-4f93-ae05-1abca7e3e557 |
Files
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: