Çankaya GCRIS Standart veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Adaptive optics correction of beam spread in biological tissues

dc.contributor.authorBaykal, Yahya
dc.date.accessioned2024-02-22T11:49:20Z
dc.date.available2024-02-22T11:49:20Z
dc.date.issued2022
dc.departmentÇankaya Üniversitesi, Mühendislik Fakültesi, Elektrik Elektronik Mühendisliği Bölümüen_US
dc.description.abstractBeam spread in turbulent biological tissues is examined when the tissue is excited with a collimated Gaussian laser beam. Adaptive optics correction is applied to the beam spread in the form of piston only (P Only), tilt only (T Only), piston+tilt (P+T), and the reduction in the beam spread is evaluated as compared to the no adaptive optics (No AO) corrected beam spread. No AO and adaptive optics corrected beam spread are expressed for various biological tissue types, against the variations in the strength coefficient of the refractive-index fluctuations, source size, small length-scale factor of turbulence, tissue length, fractal dimension, characteristic lengths of heterogeneity and the wavelength. For the examined tissue types of liver parenchyma (mouse), intestinal epithelium (mouse), upper dermis (human) and deep dermis (mouse), No AO beam spread and the adaptive optics corrected beam spread are found to increase as the strength coefficient of the refractive-index fluctuations, tissue length, fractal dimension, the characteristic lengths of heterogeneity increase, and to decrease as the source size, small length-scale factor, wavelength increase. Reduction ratio of P+T correction is almost the same for all the evaluated cases which is 74%.en_US
dc.description.publishedMonth6
dc.identifier.citationBaykal, Y. (2022). "Adaptive optics correction of beam spread in biological tissues", Journal of Quantitative Spectroscopy and Radiative Transfer, Vol.283.en_US
dc.identifier.doi10.1016/j.jqsrt.2022.108145
dc.identifier.issn224073
dc.identifier.urihttp://hdl.handle.net/20.500.12416/7286
dc.identifier.volume283en_US
dc.language.isoenen_US
dc.relation.ispartofJournal of Quantitative Spectroscopy and Radiative Transferen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAdaptive Opticsen_US
dc.subjectAdaptive Optics Correctionen_US
dc.subjectBeam Spreaden_US
dc.subjectBiological Tissue Turbulenceen_US
dc.titleAdaptive optics correction of beam spread in biological tissuestr_TR
dc.titleAdaptive Optics Correction of Beam Spread in Biological Tissuesen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: