Çankaya GCRIS Standart veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Unbalanced Operation in Transformers Used in PV Plants

dc.authorscopusid 57715481400
dc.authorscopusid 15019302900
dc.authorwosid Iskender, Ires/Aak-8084-2020
dc.authorwosid Yukselen, Emir/Kib-2167-2024
dc.contributor.author Yukselen, Emir
dc.contributor.author Iskender, Ires
dc.contributor.authorID 133746 tr_TR
dc.date.accessioned 2024-05-14T07:49:35Z
dc.date.available 2024-05-14T07:49:35Z
dc.date.issued 2022
dc.department Çankaya University en_US
dc.department-temp [Yukselen, Emir] Gazi Univ, Elect & Elect Engn Dept, Ankara, Turkey; [Yukselen, Emir] SEM Transformator Inc, Elect Design Dept, Ankara, Turkey; [Iskender, Ires] Cankaya Univ, Elect Elect Engn Dept, Ankara, Turkey en_US
dc.description.abstract energy has become the most preferred energy sources today due to its environmental and economic advantages. One of the renewable energies is solar energy, in which Photovoltaic (PV) cells are used to convert solar energy into electrical energy. In this respect, Solar Power Plant (SPP) is one of the popular renewable energy sources and the integration of such power sources into electricity grids has been increasing in recent years. Transformers are one of the largest capital investments in solar power generation and the way they work is different from transformers used in a substation. Therefore, failure of transformers has significant economic effects on electrical networks. The PV type transformer is powered by the inverter and needs to be customized to work with every system. Consequently, the safe operation and reliability of this type of transformer is critical to the sustainability of the electrical grid. Consequently, identifying the probability of failure as a preventative action for grid protection is critical and should be addressed to improve electrical system reliability. The main purpose of this study is to analyze the effects of the unbalanced operation of the inverter on the performance of the special type transformer used in the PV plant and to show how the inverter operation can affect the operation of the transformer. en_US
dc.description.publishedMonth 12
dc.description.sponsorship SEM Transformatoer Inc.; Elektro Trans Ar-Ge. Mueh. Tek. Dan. Elektronik Yaz. Taa. San. Tic. Ltd. Sti. en_US
dc.description.sponsorship The author would like to thank SEM Transformatoer Inc. and Elektro Trans Ar-Ge. Mueh. Tek. Dan. Elektronik Yaz. Taa. San. Tic. Ltd. Sti. for providing all the necessary supports. en_US
dc.description.woscitationindex Emerging Sources Citation Index
dc.identifier.citation Yükselen, Emir; Iskender, Ires (2022). "Unbalanced Operation in Transformers Used in PV Plants", International Journal of Renewable Energy Research, Vol.12, No.4, pp.2200-2205. en_US
dc.identifier.doi 10.20508/ijrer.v12i4.13596.g8586
dc.identifier.endpage 2205 en_US
dc.identifier.issn 1309-0127
dc.identifier.issn 1309-0127
dc.identifier.issue 4 en_US
dc.identifier.scopus 2-s2.0-85144822807
dc.identifier.scopusquality Q3
dc.identifier.startpage 2200 en_US
dc.identifier.uri https://doi.org/10.20508/ijrer.v12i4.13596.g8586
dc.identifier.volume 12 en_US
dc.identifier.wos WOS:000905144200021
dc.identifier.wosquality N/A
dc.language.iso en en_US
dc.publisher int Journal Renewable Energy Research en_US
dc.relation.ispartof International Journal of Renewable Energy Research en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 1
dc.subject Photovoltaic (Pv) en_US
dc.subject Solar Power Plant (Spp) en_US
dc.subject Transformer en_US
dc.subject Finite Element Method (Fem) en_US
dc.subject Unbalance Condition en_US
dc.title Unbalanced Operation in Transformers Used in PV Plants tr_TR
dc.title Unbalanced Operation in Transformers Used in Pv Plants en_US
dc.type Article en_US