Çankaya GCRIS Standart veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Unbalanced Operation in Transformers Used in PV Plants

dc.contributor.authorYükselen, Emir
dc.contributor.authorIskender, Ires
dc.contributor.authorID133746tr_TR
dc.date.accessioned2024-05-14T07:49:35Z
dc.date.available2024-05-14T07:49:35Z
dc.date.issued2022
dc.departmentÇankaya Üniversitesi, Mühendislik Fakültesi, Elektrik Elektronik Mühendisliği Bölümüen_US
dc.description.abstractRenewable energy has become the most preferred energy sources today due to its environmental and economic advantages. One of the renewable energies is solar energy, in which Photovoltaic (PV) cells are used to convert solar energy into electrical energy. In this respect, Solar Power Plant (SPP) is one of the popular renewable energy sources and the integration of such power sources into electricity grids has been increasing in recent years. Transformers are one of the largest capital investments in solar power generation and the way they work is different from transformers used in a substation. Therefore, failure of transformers has significant economic effects on electrical networks. The PV type transformer is powered by the inverter and needs to be customized to work with every system. Consequently, the safe operation and reliability of this type of transformer is critical to the sustainability of the electrical grid. Consequently, identifying the probability of failure as a preventative action for grid protection is critical and should be addressed to improve electrical system reliability. The main purpose of this study is to analyze the effects of the unbalanced operation of the inverter on the performance of the special type transformer used in the PV plant and to show how the inverter operation can affect the operation of the transformer.en_US
dc.description.publishedMonth12
dc.identifier.citationYükselen, Emir; Iskender, Ires (2022). "Unbalanced Operation in Transformers Used in PV Plants", International Journal of Renewable Energy Research, Vol.12, No.4, pp.2200-2205.en_US
dc.identifier.doi10.20508/ijrer.v12i4.13596.g8586
dc.identifier.endpage2205en_US
dc.identifier.issn13090127
dc.identifier.issue4en_US
dc.identifier.startpage2200en_US
dc.identifier.urihttp://hdl.handle.net/20.500.12416/8241
dc.identifier.volume12en_US
dc.language.isoenen_US
dc.relation.ispartofInternational Journal of Renewable Energy Researchen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectFinite Element Method (Fem)en_US
dc.subjectPhotovoltaic (Pv)en_US
dc.subjectSolar Power Plant (Spp)en_US
dc.subjectTransformeren_US
dc.subjectUnbalance Conditionen_US
dc.titleUnbalanced Operation in Transformers Used in PV Plantstr_TR
dc.titleUnbalanced Operation in Transformers Used in Pv Plantsen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: