Çankaya GCRIS Standart veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Inducing swirl flow inside the pipes of flat-plate solar collector by using multiple nozzles for enhancing thermal performance

No Thumbnail Available

Date

2021

Journal Title

Journal ISSN

Volume Title

Publisher

Pergamon-elsevier Science Ltd

Open Access Color

OpenAIRE Downloads

OpenAIRE Views

Research Projects

Organizational Units

Organizational Unit
Matematik
Bölümümüz, bilim ve sanayi için gerekli modern bilgilere sahip iş gücünü üretmeyi hedeflemektedir.

Journal Issue

Events

Abstract

In this numerical study, an attempt has been made to improve the thermal performance of the flat-plate solar collector (FPSC) by inducing the swirl flow inside the tube by the considered nozzles. To this end, the effect of the number of circumferential nozzles and their inclination angles was taken into the account. The considered number of nozzles was "single", "dual", "triple", and "quad". For each of the said cases, the inclination angle of nozzles was taken 30 degrees, 45 degrees, 60 degrees, and 90 degrees (A30, A45, A60, A90). Moreover, the mass flow rate of single-nozzle pipe was considered 0.2 kg/s, 1 kg/s, and 2 kg/s. To analyze all of the cases under identical conditions, the said mass flow rates were distributed equally among all of the nozzles (for "dual", "triple", and "quad"). All of the characteristics were defined in a form of "A...-D...- N...-M..."where "A...", "D...", "N...", and "M..." stand for angle of injection, diameter of pipe, nozzle cross-section edge, and mass flow rate, respectively. Numerical simulation (3-dimensional) of the system was performed by Finite Volume Method (FVM). The turbulence nature of flow was simulated by the k omega SST (shear stress transport) turbulent model. Results showed that the "single-nozzle"swirl generator had the highest thermal performance factor (TPF) so that for all cases its values were greater than unit. Mass flow rate growth increases Nu, heat extraction rate, and kinetic energy rate (KER) while drops friction factor and outlet temperature. Increment of injection angle increases outlet temperature and friction factor and reduces KER. The maximum and minimum values of TPF are 4.19 and 0.44 which belong to "single; A30-D50-N12.5-M0.2" and "quad; A90-D50-N12.5-M0.5", respectively. (C) 2021 Elsevier Ltd. All rights reserved.

Description

Ayed, Hamdi/0000-0001-6108-5093

Keywords

Flat Plate Solar Collector, Nozzle, Thermal Performance, Finite Volume Method (Fvm)

Turkish CoHE Thesis Center URL

Fields of Science

Citation

Cao, Yan...et al. (2021). "Inducing swirl flow inside the pipes of flat-plate solar collector by using multiple nozzles for enhancing thermal performance", Renewable Energy, Vol. 180, pp. 1344-1357.

WoS Q

Q1

Scopus Q

Q1

Source

Volume

180

Issue

Start Page

1344

End Page

1357