İnşaat Mühendisliği Bölümü
Permanent URI for this communityhttps://hdl.handle.net/20.500.12416/17
Browse
Browsing İnşaat Mühendisliği Bölümü by Author "6062"
Now showing 1 - 14 of 14
- Results Per Page
- Sort Options
annotation.listelement.badge Closure to "local Scour at Triangular Labyrinth Side Weirs Located on an Alluvial Channel" by Mustafa Tunc, Muhammet Emin Emiroglu, and Mustafa Gogus(2023) Tunç, Mustafa; Emiroğlu, Muhammet Emin; Göğüş, Mustafa; 6062Article Citation - WoS: 2Citation - Scopus: 2Critical Submergence for Single and Multiple Horizontal Intake Structures(Springer Heidelberg, 2023) Gogus, Mustafa; Gokmener, Serkan; 6062In this study, a series of experiments were carried out to investigate the variation of the critical submergence of air-entraining vortices with the related flow and geometric parameters at single and multiple horizontal intake structures. Three identical intake pipes were tested at a wide range of discharges with varying sidewall clearances under symmetrical and asymmetrical approach flow conditions. Experimental results indicated that increasing the number of intake structures in operation results in a more complicated flow pattern in front of the intake structures due to the mutual effects of the intakes on each other. Therefore, critical submergence values are higher for multiple intake structures than those of single water intake structures for a given Froude number. Dimensionless empirical equations were derived for each single, double and triple unit operation to calculate the critical submergence as a function of relevant flow and geometric parameters, and they were compared with the related equations available in the literature. These equations can be used to determine sufficient submergence to avoid air-entraining vortices at single and multiple horizontal intakes within the ranges of dimensionless parameters tested in this study.Article Citation - WoS: 6Citation - Scopus: 8Determination of hydraulic characteristics of flow over a triangular sectioned weir by using experimental and numerical modeling(Univ Tehran, Danishgah-i Tihran, 2021) Yildiz, Ali; Marti, Ali Ihsan; Gogus, Mustafa; 6062The spillways of hydraulic structures transfer excessive water from dam reservoir to the downstream in a safe and controlled manner. A labyrinth or triangular weir is a flat spillway folded in plain view. The labyrinth weirs provide an increase in crest length for a given channel width and increase the flow capacity for a given weir load. As a result of the increased flow capacity, the labyrinth and triangular weirs require less space in the dam body than the flat weirs. In this study, experiments were carried out on the labyrinth weirs containing triangles of different heights and numbers by using 3 different weir heights (P=20cm, 30cm, and 40 cm) and 4 different weir shapes. Each experiment was repeated for 30 different discharge values. The effects of weir height and weir shape on the total head over the weir (H-T) and discharge (Q) were investigated. In addition, the numerical models of all experimental setups were created by ANSYS-Fluent program using Computational Fluid Dynamics (CFD). By comparing the results obtained from the numerical models with the physical models, the accuracy of the numerical models was tested. According to the results, as the number of the triangles (N) of the weir increases, the discharge coefficient (Ca) decreases. The weir height (P) does not have a major effect on the discharge.Article Citation - WoS: 8Citation - Scopus: 9Effect of Collars on the Downstream Movement of the Maximum Scour Depth Location Around Bridge Abutments and Piers(Springer int Publ Ag, 2022) Kumcu, Serife Yurdagul; Kokpinar, Mehmet Ali; Gogus, Mustafa; 6062A detailed investigation has been conducted to study the shift location of the point of the maximum scour depth for both bridge abutment-collar and pier-collar arrangements. In the present study, an experimental program has been conducted for abutment-collar arrangements and additionally, the data obtained from the literature for the pier-collar arrangements have been revisited and analyzed to complement the framework of this study. For the abutment-collar arrangements, a series of experiments under clear-water conditions were carried out for different abutment lengths with fixed values of collar location and collar width. For pier-collar arrangements, data used from the literature have been involved constant pier diameter with various collar sizes at various elevations. To describe the locations of these maximum scour depths, their coordinates with respect to the location of the abutment or the pier were obtained. Results from this investigation showed that when a collar placed on or below the bed level was used as a countermeasure against scouring, either on an abutment or on a pier, it was observed that the maximum scour depth was routed downstream of the bridge structure.Article Citation - WoS: 0Citation - Scopus: 0Effect of Downstream Expansion of a Long-Throated Flume on Flow Properties(Gazi Univ, 2021) Hatipoglu, Murat; Gogus, Mustafa; Ucar, Muhammed; 6062Long throated flumes are widely used flow measurement devices that not requiring site-specific level to flow curves and therefore laboratory experiments. In this study, downstream expansion effect of the long throated flumes with rectangular cross section were analysed for the dimensionless parameters derived from Buckingham's pi theorem and some other known hydraulic quantities such as discharge coefficient, approach velocity coefficient, submergence ratio of the flow etc. Therefore, five downstream transitions with different expansion angles were tested. In each test, the critical depth y(c), the flow head at the depth measurement section h(1), minimum required energy dissipater length L-t and the head after hydraulic jump y(2) were measured for both modular and free flow conditions. The relation of hydraulic quantities of calculated dimensionless parameters with relevant parameters; modular limits, approach velocity coefficients and discharge coefficients etc. were graphed to represent the design relationships for long throated flumes.Article Citation - WoS: 1Citation - Scopus: 1Effect of sediment properties on incipient motion of large solitary particles on fixed bed(Emerald Group Publishing Ltd, 2021) Gogus, Mustafa; Haspolat, Emre; 6062The effect of sediment properties such as shape, size, specific weight and packing (support) condition on the incipient motion of large solitary particles was systematically investigated. A series of experiments was conducted in a rectangular tilting flume with a smooth fixed (rigid) bed under uniform flow conditions. In each experiment, a thin fibreglass rectangular rod of height 1/5 or 1.5/5 of the height of the particle was placed just downstream of the particle to imitate the interaction of particles in rivers. Contrary to common belief and knowledge, it was found that the Shields parameter decreased as the dimensionless grain diameter increased for a given bed slope under rough turbulent flow conditions. Moreover, a larger shear stress was needed to start the motion of particles on steeper slopes for a given particle diameter. An increase in the ratio of the support height to particle height by 50% resulted in an increase in the dimensionless critical shear stress by almost six times for the same particle and relative roughness.Conference Object Citation - Scopus: 0Effects of Floating Rafts as Anti-Vortex Devices at Horizontal Intakes(International Association for Hydro-Environment Engineering and Research, 2023) Gogus, M.; Gokmener, S.; 6062Air- entraining vortices created by swirling flows on intakes cause serious problems such as; increasing loss of hydraulic load and discharge at water intake structures, loss of efficiency, operational problems, cavitation and vibration problems in hydraulic machines. Hence the position of the intake should be justified for the most critical scenario as the reservoir is at dead or at minimum storage level to avoid the occurrence of air-entraining vortices. Although intakes are designed by considering the formation of air-entraining vortices, they cannot be prevented due to approach flow conditions and submergence. Therefore, some structural changes should be considered in order to avoid the occurrence of air-entraining vortices. One of these methods is using anti-vortex devices to prevent the formation of air-entraining vortices. In this experimental study, floating rafts at different sizes were tested as anti-vortex devices to prevent the formation of air-entraining vortices at single and multiplehorizontal intake structures under symmetrical and asymmetrical approach flow conditions. Three identical pipes of diameter Di=0.265 m were tested at a wide range of discharge with varying sidewall clearances. Experiments were conducted for three different combinations of the intake structures: single, double and triple water intakes were operated, respectively. Different side wall distances in the approach channels of the intake structures were specified previously to create symmetrical and asymmetrical flow conditions. The side walls were located according to these distances before each experiment. For single and double water intake structures, Wraft=10 cm and triple water intake structures, Wraft=20 cm raft width were found to be successful for vortex prevention. Moreover, Wrafts/Di values that gave successful results are 0.38 for single and double intake structures and 0.75 for triple intake structures. © 2023 IAHR – International Association for Hydro-Environment Engineering and ResearchArticle Citation - WoS: 4Citation - Scopus: 4Estimation of Critical Submergence at Single Horizontal Intakes Under Asymmetric Flow Conditions(Springer Heidelberg, 2022) Haspolat, Emre; Gogus, Mustafa; 6062Air-entraining vortices are one of the serious hydraulic phenomena which can create various problems during the operation of intakes. Generally, air-entraining vortices start to form when the intake submergence is insufficient and less than a critical value. The purpose of the present study is to investigate the formation of air-entraining vortices and determine the critical submergences at single horizontal intake under asymmetrical approach flow conditions by conducting experiments with four different pipe diameters. In the experiments, various sidewall clearances with a series of discharges were tested for a given pipe diameter to examine the effect of dimensionless flow and geometric parameters on the critical submergence. Based on dimensional analysis, empirical equations were derived to predict critical submergence by performing regression analyses of relevant dimensionless parameters. Scale effect analysis was also carried out to investigate the effect of neglected flow parameters on the critical submergence in the application of model similitude law. A formula that makes it possible to transform model results into prototype results in the range of tested parameters was derived and compared with similar studies mostly based on existing installations. Eventually, it was pointed out that the result of the model study underestimates critical submergence compared to others due to the scale effects. Moreover, it was determined that critical submergences at intakes having asymmetrical approach flow conditions are higher than those of symmetrical approach flows.Article Citation - WoS: 0Citation - Scopus: 0Experimental Study on the Interaction Between Bridge Pier and Abutment Concerning Clear-Water Local Scour(Springer int Publ Ag, 2023) Akbulut, Omer Faruk; Kokpinar, Mehmet Ali; Gogus, Mustafa; 6062Estimation of scour depth around bridge piers and abutments is essential for safety and economic design in alluvial rivers. Although local scour around bridge piers and abutments has been studied separately by a large number of investigators, there is limited research on the literature related to the interaction between these two structures. Hence, in this study, the aim is to investigate the interaction between bridge abutments and pier scours in detail. For this reason, bridge abutments of different lengths of La = 0.05, 0.10, and 0.15 m and a pier with diameter of D = 0.1 m were placed at various distances from each other in a long sediment channel and tested under clear-water flow conditions with constant flow intensity. All the important dimensionless parameters involved in the interaction phenomenon were derived from theoretical analysis, and the relationships between them were investigated. Analysis of the data showed that the presence of a pier in the flow medium in addition to an abutment has a certain amount of influence on the formation of scour holes around the structures. The influence of the abutment on the pier was more noticeable in the current study, particularly for longer abutments, leading to average increases of up to 20% in scour depth around the pier. The study's findings revealed that the presence of both a pier and an abutment in the flow medium exerted a discernible, unfavorable influence on the development of scour holes, particularly around piers.Article Citation - Scopus: 0Farklı savak yüksekliğine ve konfigürasyona sahip dairesel labirent savakların deneysel modellenmesi(Gumushane University, 2023) Yildiz, A.; Marti, A.İ.; Göğüş, M.; 6062Due to their zigzag geometry in plain view, labyrinth weirs require less crest length compared to linear weirs in the dam body or in the channels where they are placed. In this study, the effect of the number of cycles (N) and weir heights (P) of the semi-circular labyrinth weirs on the flow efficiency was investigated. Semi-circular labyrinth weirs, unlike triangular and trapezoidal labyrinth weirs, increase the discharge efficiency by making the areas that reduce the flow capacity at the intersection areas more efficient and by allowing the flow to move in a more perpendicular direction to the weir walls. The experiments were carried out on 3 different configurations (N=2, 3 and 4) depending on the number of semi-circles they contain. In all configurations, a total of 3 weir heights (P=0.20, 0.30 m and 0.40 m) were used and 9 test setups were prepared. In addition, to reference the results obtained from circular weirs, experiments were carried out with linear weirs at 3 different weir heights (P=0.20, 0.30 m and 0.40 m), and a total of 12 experiments were carried out. n this study, the effect of the number of cycles (N) and weir heights (P) of the semicircular labyrinth weirs on the discharge efficiency was investigated. The results obtained from the circular labyrinth weir experiments were compared with previous studies and it was seen that the semi-circular labyrinth weirs had higher discharge capacity than the triangular labyrinth weirs. In addition, semi-circular labyrinth weirs provided a longer effective crest length than the triangular form with the same channel width, they provide higher flow rates at the same weir load. © 2023, Gumushane University. All rights reserved.Article Citation - WoS: 1Citation - Scopus: 1Hydraulics of circular bottom intake orifices(Wiley, 2021) Gogus, Mustafa; Bulut, Muhammed; Ucar, Muhammed; 6062In this study, the hydraulic characteristics of circular bottom intake orifices were investigated in a hydraulic model. The structure diverts the river-flow to a hydroelectric power plant through circular orifices located at the bottom of the channel. In the model, a series of circular holes of various diameters and locations at the bottom of a channel in the form of single and multiple holes were tested for different flowrates and screen angles (theta) to determine the flow diverting capacity of them. Discharges passing through orifices at known locations (x) and diameters (d) and screen slopes (theta) were measured and recorded along with the related main channel flow rates and depths (h). Using the dimensional analysis approach, an expression for the flow rate diverted from the main channel was derived as a function of related parameters, and their variations with each other were presented graphically and empirical equations were determined. Referring to the graphs and empirical equations, one can determine the discharge capacity of single and multiple intake orifices, which is important to calculate the amount of flow to be diverted from the main channel within the ranges of the related parameters used in this study.Article Citation - WoS: 2Citation - Scopus: 2Local scour evolution around semi-circular end bridge abutment in quasi-unsteady condition(Ice Publishing, 2022) Gokmener, Serkan; Gogus, Mustafa; 6062In this experimental study, the temporal development of local scour is studied around semi-circular end bridge abutments under quasi-unsteady clear-water flow conditions in a rectangular sediment channel. A step-wise hydrograph of 6 h duration is used in the experiments. Six different abutment lengths having constant width, with uniform sand as bed material, were tested for three different successive flows - each applied continuously for 2 h. Bathymetry of the bed level was measured around the abutment every 15 min with the help of a measurement device to observe temporal development of the local scour around the semi-circular end abutment. Effects of the abutment length, flow intensity and time on the scour depths around semi-circular end bridge abutments, along with those at the front, upstream and downstream faces of the abutment, are also investigated and discussed. It is shown that the maximum scour depth always occurs at the front noses of the abutments compared with those at the upstream and downstream noses. A dimensionless empirical formula is derived to predict the scour depth at the front nose of the abutment as a function of related parameters. The results reveal that flow intensity is the most critical parameter in scour development.Article Citation - WoS: 3Citation - Scopus: 3Numerical and experimental modelling of flow at Tyrolean weirs(Elsevier Sci Ltd, 2021) Yildiz, Ali; Marti, Ali Ihsan; Gogus, Mustafa; 6062In this study, a small-scaled Tyrolean weir model was constructed in the laboratory environment and a series of experiments were conducted on it, for two different rack inclinations (theta(1) = 18 degrees and theta(2) = 25 degrees) and three different bar spacings (e(1) = 3 mm, e(2) = 6 mm and e(3) = 10 mm) for a range of upstream flow discharges. The flow rates passing through the racks and going downstream over the racks were measured. Empirical equations for the discharge coefficient and water capture capacity of the Tyrolean weirs were determined by applying dimensional analysis to the parameters involved in the phenomenon. The related dimensionless parameters were presented with graphs and empirical equations for discharge coefficients were derived, coefficient of determination R-2 of equations for theta(1) = 18 degrees and theta(2) = 25 degrees are found 0.838 and 0.825 respectively. According to results obtained from experimental data, C-d increases as the Froude number ((F-r)(e)) between bars increases and water capture capacity [(q(w))(i)/(q(w))(T)] of the racks decreases with increasing ((F-r)(e)). Also, a numerical model of the Tyrolean weir was generated by using Flow-3D software and it was shown that the results of the numerical analysis were very consistent with the physical model results at large bar spacing such as e = 10 mm. As the bar spacing (e) reduces, the success of the numerical model giving consistent results with physical model is decreasing.Article Citation - WoS: 1Citation - Scopus: 1The Performance Of Water Jet Pumps And Their Applicatıon In Slurry Transportation(Turkish Soc thermal Sciences Technology, 2023) Kokpinar, Mehmet Ali; Gogus, Mustafa; 6062This present work is focused firstly on an experimental investigation for the optimum design of water jet pumps to be used in the hydrotransport of solid particles through pipeline systems. Experiments were conducted in a closed test loop using five types of jet pumps with various dimensions of the driving nozzle, suction nozzle, mixing chamber, and diffuser employing water as driving and suction fluid. The efficiency of each water jet pump element was analyzed and interpretations of results related to each water jet pump were made about the parts to be considered in the optimum design of a water jet pump. From the experimental results, the water jet pump having the optimum mixing chamber, suction nozzle, driving nozzle location, and cross-sectional dimensions produced a maximum efficiency of about 33%. In the second part of the study, the solid particle carrying capacity of water jet pumps in a pipeline system was studied under saltation, moving bed, and heterogeneous flow regimes by introducing seven different types of solid particles having various concentrations into the closed test loop. The effect of jet pumps on separating solid particles from flow in a region was investigated. A curved form of a by-pass system called the 'flow division unit' was added to the main pipeline system and through the flow division unit, then most of the solid particles in the flow were forced to flow towards the suction pipe of the jet pump. As a result of this, only water with very small particle concentrations passed through the centrifugal pumps, and in this way, the wear risk of the centrifugal pump was reduced considerably.