PubMed İndeksli Yayınlar Koleksiyonu
Permanent URI for this collectionhttps://hdl.handle.net/20.500.12416/8650
Browse
Browsing PubMed İndeksli Yayınlar Koleksiyonu by Author "Baleanu, D"
Now showing 1 - 8 of 8
- Results Per Page
- Sort Options
Article A zero-crossing technique for the multidetermination of thiamine HCl and pyridoxine HCl in their mixture by using one-dimensional wavelet transform(Elsevier, 2003) Dinç, E; Baleanu, Dumitru; Baleanu, D; 56389A new zero-crossing technique based on one-dimensional wavelet transform (WT) was developed and applied on a commercial vitamin product and binary mixtures containing thiamine HCl and pyridoxine HCl in the presence of the interference of the analysed signals. We selected from the data of the UV-Vis absorption spectra a signal consisting of 1150 points corresponding to the concentration range 8-32 mg/ml for both vitamins and we subjected it to one-dimensional continuous WT Mexican (MEXICAN) and Meyer (MEYER). Since the peaks of the transformed signals were bigger than original ones a zero crossing technique was applied to obtain the regression equations. The validity of Beer-Lambert law was assumed for the transformed signals. An appropriate scale setting was choosing to obtain an alternative calibration for each method. The basic concepts about wavelet method were briefly explained and MATLAB 6.5 software was used for one-dimensional wavelet analysis, The obtained results were successfully compared among each other and with those obtained by other literature methods. The developed method is rapid, easy to apply. not expensive and suitable for analysing of the overlapping signals of compounds in their mixtures without any chemical pre-treatment. (C) 2003 Elsevier Science B.V. All rights reserved.Article An application of derivative and continuous wavelet transforms to the overlapping ratio spectra for the quantitative multiresolution of a ternary mixture of paracetamol, acetylsalicylic acid and caffeine in tablets(Elsevier Science Bv, 2005) Dinç, E; Baleanu, Dumitru; Özdemir, A; Baleanu, D; 56389Quantitative multi resolution of tablets and ternary mixtures of paracetamol (PAR), acetylsalicylic acid (ASP) and caffeine (CAF) having strongly overlapping spectra was accomplished by two graphical transform methods as ratio spectra first derivative-zero crossing and ratio spectra-continuous wavelet transform-zero crossing (ratio spectra CWT-zero crossing) methods. In this study, ratio spectra derivative-zero crossing and ratio spectra CWT-zero crossing methods are based on the use of transformed signals of the ratio spectra and their calibration graphs were obtained by measuring the dA/dlambda and CWT amplitudes of the ratio spectra corresponding to zero crossing points. For the comparison purpose. PLS calibration method was applied to predict the content of the same mixtures containing the subject active Compounds. The obtained calibrations were tested by using the synthetic mixtures and standard addition technique and they applied to the simultaneous determination of PAR, ASP and CAF in commercial pharmaceutical preparation. The obtained results were statistically compared with each other as well as those obtained by HPLC method and they showed good agreement. (C) 2004 Published by Elsevier B.V.Article Chemometric Determination of Naproxen Sodium and Pseudoephedrine Hydrochloride in Tablets by HPLC(Pharmaceutical Soc Japan, 2006) Dinç, E; Baleanu, Dumitru; Özdemir, A; Aksoy, H; Üstündag, Ö; Baleanu, D; 6981; 26096; 105547A new chemometric determination by high-performance liquid chromatography (HPLC) with photodiode array (PDA) detection was implemented for the simultaneous determination of naproxen sodium and pseudoephedrine hydrochloride in tablets. Three chemometric calibration techniques, classical least squares (CLS), principle component regression (PCR) and partial least squares (PLS) were applied to the peak area at multiwavelength PDA detector responses. The combinations of HPLC with chernometric calibration techniques were called HPLC-CLS, HPLC-PCR and HPLC-PLS. For comparison purposes the HPLC method called the classic HPLC method was used to confirm the results obtained from combined HPLC-chemometric calibration techniques. A good chromatographic separation between two drugs with losartan potassium as an internal standard was achieved using a Waters Symmetry (R) C18 Column 5 mu m 4.6 +/- 250 mm and a mobile phase containing 0.2 m acetate buffer and acetonitrile (v/v, 40 : 60). The multiwavelength PDA detection was measured at five different wavelengths. The chromatograms were recorded as a training set in the mobile phase. Three HPLC-chemometric calibrations and the classic-HPLC method were used to test the synthetic mixtures of naproxen sodium and pseudoephedrine hydrochloride in the presence of the internal standard. The HPLC-chemometric approaches were applied to real samples containing drugs of interest. The experimental results obtained from HPLC-chemometric calibrations were compared with those obtained by a classic HPLC method.Article Comparative study of the continuous wavelet transform, derivative and partial least squares methods applied to the overlapping spectra for the simultaneous quantitative resolution of ascorbic acid and acetylsalicylic acid in effervescent tablets(Elsevier Science Bv, 2005) Dinç, E; Baleanu, Dumitru; Ozdemir, A; Baleanu, D; 56389The simultaneous spectrophotometric determination of ascorbic acid (AA) and acetylsalicylic acid (ASA) in effervescent tablets in the presence of the overlapping spectra was accomplished by the continuous wavelet transform (CWT), derivative spectrophotometry (DS) and partial least squares (PLS) approaches without using any chemical pre-treatment. CWT and DS calibration equations for AA and ASA were obtained by measuring the CWT and DS amplitudes corresponding to zero-crossing points of spectra obtained by plotting continuous wavelet coefficients and first-derivative absorbance values versus the wavelengths, respectively. The PLS calibration was constructed by using the concentration set and its full absorbance data consisting of 850 points from 220 to 305 urn in the range of 210-310 nun. These three methods were tested by analyzing the synthetic mixtures of the above drugs and they were applied to the real samples containing two commercial pharmaceutical preparations of subjected drugs. A comparative study was carried out by using the experimental results obtained from three analytical methodologies and precise and accurate results were obtained. (c) 2004 Published by Elsevier B.V.Article Multidetermination of thiamine HC1 and pyridoxine HC1 in their mixture using continuous daubechies and biorthogonal wavelet analysis(Elsevier Science Bv, 2003) Dinç, E; Baleanu, Dumitru; Baleanu, D; 56389A new graphical method based on the one-dimensional wavelet transform (WT) was proposed and tested on mixture of thiamine hydrochloride (THI) and pyridoxine hydrochloride (PYR) in the presence of strongly overlapping signals. We selected from the data of the UV-VIS absorption spectra a signal consisting of 1150 points corresponding to the concentration range 8-32 mg ml(-1) for each vitamin and we subjected it to Daubechies8 (DAUB8) and Biorthogonal6.8 (BIOR6.8) wavelet transforms. Since the peaks of the transformed signals were bigger than original ones a zero crossing method was applied to obtain the calibration graphs. In addition, the validity of Beer-Lambert law was assumed for the transformed signals. An appropriate scale setting was choosing to obtain an alternative calibration for each method. MATLAB 6.5 software was used for one-dimensional wavelet analysis and the basic concepts about wavelet method were given. The obtained results were successfully compared among each other as well as with those obtained by other literature methods. The method developed in this paper is rapid, easy to apply, not expensive and it is suitable for analyzing of the overlapping signals of compounds in their mixtures without any chemical pre-treatment. (C) 2002 Elsevier Science B.V. All rights reserved.Article Spectrophotometric multicomponent analysis of a mixture of metamizol, acetaminophen and caffeine in pharmaceutical formulations by two chemometric techniques(Pergamon-elsevier Science Ltd, 2001) Dinç, E; Baleanu, Dumitru; Baleanu, D; Onur, F; 56389Inverse least squares (ILS) and factor-based (principal component analysis (PCA)) techniques were proposed for the spectrophotometric multicomponent analysis of a ternary mixture consisting of metamizol, acetaminophen and caffeine, without prior separation. In these chemometric techniques, the measurements of the absorbance values were realized in the spectral range from 225 to 285 nm in the intervals of Delta lambda = 5 nm at the 13 wavelengths in the zero-order spectra of the different ternary mixtures of these active ingredients in 0.1 M HCl. The prepared calibrations of both techniques using the absorbance data and concentration matrix data sets were used to predict the concentration of the unknown concentrations of metamizol acetaminophen and caffeine in their ternary mixture. The 'MAPLE V' software was used for the numerical calculations, Mean recoveries and relative standard deviations for ILS and PCA techniques were found to be 99.8 and 1.68%, 99.9 and 1,66% for caffeine, 99.8 and 1.84%, 100.4 and 2.85% for metamizol, and 99.7 and 1.04%, 99.6 and 1.34/ for acetaminophen, respectively, for the first and second techniques. The techniques were successfully applied to two pharmaceutical formulations marketed in Turkey and results were compared with a new high-performance liquid chromatography method. (C) 2001 Elsevier Science B.V. All rights reserved.Conference Object Spectrophotometric quantitative determination of cilazapril and hydrochlorothiazide in tablets by chemometric methods(Pergamon-elsevier Science Ltd, 2002) Dinç, E; Baleanu, Dumitru; Baleanu, D; 56389Four chemometric methods were applied to simultaneous determination of cilazapril and hydrochlorothiazide in tablets. Classical least-square (CLS), inverse least-square (ILS), principal component regression (PCR) and partial least-squares (PLS) methods do not need any priori graphical treatment of the overlapping spectra of two drugs in a mixture. For all chemometric calibrations a concentration set of the random mixture consisting of the two drugs in 0.1 M HCl and methanol (1:1) was prepared. The absorbance data in the UV-Vis spectra were measured for the 15 wavelength points (from 222 to 276 nm) in the spectral region 210-290 nm considering the intervals of Deltalambda = 4 nm. The calibration of the investigated methods involves only absorbance and concentration data matrices. The developed calibrations were tested for the synthetic mixtures consisting of two drugs and using the Maple V software the chemometric, calculations were performed. The results of the methods were compared each other as well as with HPLC method and a good agreement was found. (C) 2002 Elsevier Science B.V. All rights reserved.Article Two new spectrophotometric approaches to the multicomponent analysis of the acetaminophen and caffeine in tablets by classical least-squares and principal component regression techniques(Elsevier Science Sa, 2002) Dinç, E; Baleanu, Dumitru; Baleanu, D; 56389Classical least-squares (CLS) and principal. component regression (PCR) techniques were proposed for the simultaneous analysis of tablets containing acetaminophen and caffeine without using a chemical separation procedure. The chemometric calibrations were prepared by measuring the absorbances values at the 15 wavelengths in the spectral region 215-285 nm and by using a training set of the mixtures of both drugs in 0.1 M HCl. The obtained chemometric calibrations were used for the estimation of acetaminophen and caffeine in samples. The numerical calculations were performed with the 'MAPLE V' software. By applying two techniques to synthetic mixtures, the mean recoveries and the relative standard deviations in the CLS and PCR techniques were found as 99.5 and 1.29, 99.7 and 1.00% for acetaminophen and 99.9 and 1.92, 100.0 and 1.178% for caffeine, respectively. Our results were compared with those obtained previously by one of us considering HPLC method as a reference method. These two methods were successfully applied to a pharmaceutical tablet formulation of two drugs. (C) 2002 Elsevier Science S.A. All rights reserved.