WoS İndeksli Yayınlar Koleksiyonu
Permanent URI for this collectionhttps://hdl.handle.net/20.500.12416/8653
Browse
3 results
Search Results
Article Citation - WoS: 6Citation - Scopus: 7Spectrophotometric Multicomponent Determination of Tetramethrin, Propoxur and Piperonyl Butoxide in Insecticide Formulation by Principal Component Regression and Partial Least Squares Techniques With Continuous Wavelet Transform(Spectroscopy Soc Canada, Ottawa, 2004) Dinç, E; Baleanu, Dumitru; Baleanu, D; Kanbur, M; MatematikA continuous wavelet transform (CWT) followed by a principal component regression(PCR) and partial least squares (PLS) were applied for the quantitative determination of tetramethrin (TRM), propoxur (PPS) and piperonil butoxide (PPR) in their formulations. Absorbances of the concentration set formed by TRM, PPS and PPR mixtures were measured at 850 points between 220-350 nm with 0.1 nm intervals, and their absorbance values as absorbance data vectors were transferred into the wavelets domain. A CWT was applied to the absorbance data. The resulting CWT-coefficients (x-block) and concentration set (y-block) were used for the construction of CWT-PCR and CWT-PLS calibrations. The combination of both continuous wavelet and chemometrics techniques indicates good results for the determination of insecticide in synthetic mixtures and commercial formulation.Article Citation - WoS: 72Citation - Scopus: 81An Application of Derivative and Continuous Wavelet Transforms To the Overlapping Ratio Spectra for the Quantitative Multiresolution of a Ternary Mixture of Paracetamol, Acetylsalicylic Acid and Caffeine in Tablets(Elsevier Science Bv, 2005) Özdemir, A; Baleanu, D; Dinç, EQuantitative multi resolution of tablets and ternary mixtures of paracetamol (PAR), acetylsalicylic acid (ASP) and caffeine (CAF) having strongly overlapping spectra was accomplished by two graphical transform methods as ratio spectra first derivative-zero crossing and ratio spectra-continuous wavelet transform-zero crossing (ratio spectra CWT-zero crossing) methods. In this study, ratio spectra derivative-zero crossing and ratio spectra CWT-zero crossing methods are based on the use of transformed signals of the ratio spectra and their calibration graphs were obtained by measuring the dA/dlambda and CWT amplitudes of the ratio spectra corresponding to zero crossing points. For the comparison purpose. PLS calibration method was applied to predict the content of the same mixtures containing the subject active Compounds. The obtained calibrations were tested by using the synthetic mixtures and standard addition technique and they applied to the simultaneous determination of PAR, ASP and CAF in commercial pharmaceutical preparation. The obtained results were statistically compared with each other as well as those obtained by HPLC method and they showed good agreement. (C) 2004 Published by Elsevier B.V.Article Citation - WoS: 51Citation - Scopus: 56Comparative Study of the Continuous Wavelet Transform, Derivative and Partial Least Squares Methods Applied To the Overlapping Spectra for the Simultaneous Quantitative Resolution of Ascorbic Acid and Acetylsalicylic Acid in Effervescent Tablets(Elsevier Science Bv, 2005) Ozdemir, A; Baleanu, D; Dinç, EThe simultaneous spectrophotometric determination of ascorbic acid (AA) and acetylsalicylic acid (ASA) in effervescent tablets in the presence of the overlapping spectra was accomplished by the continuous wavelet transform (CWT), derivative spectrophotometry (DS) and partial least squares (PLS) approaches without using any chemical pre-treatment. CWT and DS calibration equations for AA and ASA were obtained by measuring the CWT and DS amplitudes corresponding to zero-crossing points of spectra obtained by plotting continuous wavelet coefficients and first-derivative absorbance values versus the wavelengths, respectively. The PLS calibration was constructed by using the concentration set and its full absorbance data consisting of 850 points from 220 to 305 urn in the range of 210-310 nun. These three methods were tested by analyzing the synthetic mixtures of the above drugs and they were applied to the real samples containing two commercial pharmaceutical preparations of subjected drugs. A comparative study was carried out by using the experimental results obtained from three analytical methodologies and precise and accurate results were obtained. (c) 2004 Published by Elsevier B.V.
