Bilgilendirme: Kurulum ve veri kapsamındaki çalışmalar devam etmektedir. Göstereceğiniz anlayış için teşekkür ederiz.
 

Mousa, Ayad

Loading...
Profile Picture
Name Variants
Mousa, A
Job Title
Öğr. Gör.
Email Address
Main Affiliation
Bilgisayar Mühendisliği
Status
Former Staff
Website
ORCID ID
Scopus Author ID
Turkish CoHE Profile ID
Google Scholar ID
WoS Researcher ID

Sustainable Development Goals

SDG data is not available
This researcher does not have a Scopus ID.
This researcher does not have a WoS ID.
Scholarly Output

1

Articles

1

Views / Downloads

2/0

Supervised MSc Theses

0

Supervised PhD Theses

0

WoS Citation Count

8

Scopus Citation Count

8

WoS h-index

1

Scopus h-index

1

Patents

0

Projects

0

WoS Citations per Publication

8.00

Scopus Citations per Publication

8.00

Open Access Source

0

Supervised Theses

0

Google Analytics Visitor Traffic

JournalCount
Physiological Measurement1
Current Page: 1 / 1

Scopus Quartile Distribution

Competency Cloud

GCRIS Competency Cloud

Scholarly Output Search Results

Now showing 1 - 1 of 1
  • Article
    Citation - WoS: 8
    Citation - Scopus: 8
    Comparative Analysis on Wavelet-Based Detection of Finite Duration Low-Amplitude Signals Related To Ventricular Late Potentials
    (Iop Publishing Ltd, 2004) Mousa, A; Yilmaz, A
    Ventricular late potentials (VLPs) are considered as a noninvasive marker of patients with myocardial infarction, who are prone to the development of ventricular tachycardia. This paper investigates the effects of variations in physical properties of myocardial infarcts in terms of their effects on the parametric variations in VLP analysis. A sufficiently large set of signals underlining the behavior of physical parameters was employed to represent the effect of physical size, position, orientation and type of infarct. The approximated signals are variations from real electrocardiography signals by adding potentials representing late potentials based on duration, frequency, amplitude and position. The aim is not to exactly model VLP but rather to generate an approximate set of signals to examine the performance of the standard methods for different possibilities in infarct dynamics. We investigate some of the detection approaches together with their related assumptions, and try to pinpoint the drawbacks and inaccuracies of these methods and also their assumptions. The three widely accepted criteria-QRS duration, root-mean-square and duration of the signal at the end of QRS for VLP detection-were used in the investigation. Results from the application of these parameters to the set of signals are presented. In addition we investigate the physical nature of an infarct and list a number of possible reasons that might be the cause of a low success rate for the detection of additive potentials. To improve the performance of the common methods, two more wavelet transform parameters are added to those of the standard methods. The method derived from this analysis is presented as an alternative means for the detection of late signals named as delayed potentials, a more general class that includes VLP as a subset.