Bilgilendirme: Kurulum ve veri kapsamındaki çalışmalar devam etmektedir. Göstereceğiniz anlayış için teşekkür ederiz.
 

Nimrad: Novel Technique for Respiratory Data Treatment

dc.contributor.author Nigmatullin, R. R.
dc.contributor.author Ionescu, C.
dc.contributor.author Baleanu, D.
dc.date.accessioned 2022-07-25T13:39:32Z
dc.date.accessioned 2025-09-18T12:47:57Z
dc.date.available 2022-07-25T13:39:32Z
dc.date.available 2025-09-18T12:47:57Z
dc.date.issued 2014
dc.description Ionescu, Clara Mihaela/0000-0001-7685-035X en_US
dc.description.abstract This paper illustrates the efficiency and simplicity of a new technique which is determined in this paper as NIMRAD (the non-invasive methods of the reduced analysis of data) for describing information extracted from biological signals. As a specific example, we consider the respiratory data. The NIMRAD can be applied for quantitative description of data recorded for complex systems in cases where the adequate model is absent and the treatment procedure should not contain any uncontrollable error. The theoretical developments are applied to signals measured from the respiratory system by means of the forced oscillation technique based on non-invasive lung function test. In order to verify the feasibility of the proposed algorithm for developing new diagnosis tools, we apply NIMRAD on two different respiratory data sets, namely from a healthy subject and from a patient diagnosed with asthma. The results are promising and suggest that NIMRAD could be further tailored and used for specific clinical applications. en_US
dc.identifier.citation Nigmatullin, R. R.; Ionescu, C.; Baleanu, D. (2014). "NIMRAD: novel technique for respiratory data treatment", SIGNAL IMAGE AND VIDEO PROCESSING, Vol. 8., No. 8., pp. 1517-1532. en_US
dc.identifier.doi 10.1007/s11760-012-0386-1
dc.identifier.issn 1863-1711
dc.identifier.issn 1863-1703
dc.identifier.scopus 2-s2.0-84893854080
dc.identifier.uri https://doi.org/10.1007/s11760-012-0386-1
dc.identifier.uri https://hdl.handle.net/20.500.12416/11943
dc.language.iso en en_US
dc.publisher Springer London Ltd en_US
dc.relation.ispartof Signal, Image and Video Processing
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Non-Invasive Data Treatment Methods en_US
dc.subject Respiratory Impedance en_US
dc.subject Asthma Diagnosis en_US
dc.title Nimrad: Novel Technique for Respiratory Data Treatment en_US
dc.title NIMRAD: novel technique for respiratory data treatment tr_TR
dc.type Article en_US
dspace.entity.type Publication
gdc.author.id Ionescu, Clara Mihaela/0000-0001-7685-035X
gdc.author.scopusid 7006385494
gdc.author.scopusid 7102287005
gdc.author.scopusid 7005872966
gdc.author.wosid Nigmatullin, Raoul/Aao-5504-2020
gdc.author.wosid Baleanu, Dumitru/B-9936-2012
gdc.author.wosid Ionescu, Clara Mihaela/O-7006-2014
gdc.author.yokid 56389
gdc.bip.impulseclass C4
gdc.bip.influenceclass C4
gdc.bip.popularityclass C5
gdc.coar.access metadata only access
gdc.coar.type text::journal::journal article
gdc.collaboration.industrial false
gdc.description.department Çankaya University en_US
gdc.description.departmenttemp [Nigmatullin, R. R.] Kazan Fed Univ, Inst Phys, Dept Theoret Phys, Kazan 420008, Russia; [Ionescu, C.] Univ Ghent, Dept Elect Energy Syst & Automat, B-9052 Ghent, Zwijnaarde, Belgium; [Baleanu, D.] Cankaya Univ, Dept Math, TR-06530 Ankara, Turkey; [Baleanu, D.] King Abdulaziz Univ, Dept Chem & Mat Engn, Fac Engn, Jeddah 21589, Saudi Arabia; [Baleanu, D.] Inst Space Sci, Magurele 76900, Romania en_US
gdc.description.endpage 1532 en_US
gdc.description.issue 8 en_US
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality Q2
gdc.description.startpage 1517 en_US
gdc.description.volume 8 en_US
gdc.description.woscitationindex Science Citation Index Expanded
gdc.description.wosquality Q3
gdc.identifier.openalex W2058111324
gdc.identifier.wos WOS:000344621800011
gdc.index.type WoS
gdc.index.type Scopus
gdc.oaire.diamondjournal false
gdc.oaire.impulse 5.0
gdc.oaire.influence 3.5880838E-9
gdc.oaire.isgreen false
gdc.oaire.keywords Asthma diagnosis
gdc.oaire.keywords 600
gdc.oaire.keywords Non-invasive data treatment methods
gdc.oaire.keywords 620
gdc.oaire.keywords Respiratory impedance
gdc.oaire.popularity 1.9661572E-9
gdc.oaire.publicfunded false
gdc.oaire.sciencefields 03 medical and health sciences
gdc.oaire.sciencefields 0302 clinical medicine
gdc.openalex.collaboration International
gdc.openalex.fwci 1.8153
gdc.openalex.normalizedpercentile 0.84
gdc.opencitations.count 17
gdc.plumx.crossrefcites 9
gdc.plumx.mendeley 11
gdc.plumx.scopuscites 15
gdc.publishedmonth 12
gdc.scopus.citedcount 15
gdc.virtual.author Baleanu, Dumitru
gdc.wos.citedcount 11
relation.isAuthorOfPublication f4fffe56-21da-4879-94f9-c55e12e4ff62
relation.isAuthorOfPublication.latestForDiscovery f4fffe56-21da-4879-94f9-c55e12e4ff62
relation.isOrgUnitOfPublication 26a93bcf-09b3-4631-937a-fe838199f6a5
relation.isOrgUnitOfPublication 28fb8edb-0579-4584-a2d4-f5064116924a
relation.isOrgUnitOfPublication 0b9123e4-4136-493b-9ffd-be856af2cdb1
relation.isOrgUnitOfPublication.latestForDiscovery 26a93bcf-09b3-4631-937a-fe838199f6a5

Files