Çankaya GCRIS Standart veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Experimental study on the sensitivity of autocalibration to projective camera model parameters

dc.authorid Atalay, Volkan/0000-0001-7850-0601
dc.authorscopusid 56086374000
dc.authorscopusid 6602757969
dc.authorwosid Atalay, Volkan/M-2256-2016
dc.contributor.author Hassanpour, Reza
dc.contributor.author Hassanpour, Reza
dc.contributor.author Atalay, Volkan
dc.contributor.authorID 48646 tr_TR
dc.contributor.other Yazılım Mühendisliği
dc.date.accessioned 2016-04-01T07:22:37Z
dc.date.available 2016-04-01T07:22:37Z
dc.date.issued 2006
dc.department Çankaya University en_US
dc.department-temp Cankaya Univ, Dept Comp Engn, Ankara, Turkey; Middle E Tech Univ, Dept Comp Engn, TR-06531 Ankara, Turkey en_US
dc.description Atalay, Volkan/0000-0001-7850-0601 en_US
dc.description.abstract Existing methods of 3-D object modeling and recovering 3-D data from uncalibrated 2-D images are subject to errors introduced by assumptions about camera parameters and mismatches in finding point pairs in the images. In this study, we experimentally evaluate the effect of each of these assumptions together with the inaccuracy in the measurements in the images. Sensitivity of reconstruction errors to inaccuracies in the estimation of camera parameters and mismatches due to noise in input data is measured using a linear and two nonlinear autocalibration methods for a projective camera. Our experimental results show that some assumptions such as a vanishing skew can be safely made; however, other parameters such as principal point location are quite sensitive to wrong assumptions. (c) 2006 Society of Photo-Optical Instrumentation Engineers. en_US
dc.description.publishedMonth 4
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.citation Hassanpour, R., Atalay, V., (2006). Experimental study on the sensitivity of autocalibration to projective camera model parameters. Optical Engineering, 45(4). http://dx.doi.org/10.1117/1.2189292 en_US
dc.identifier.doi 10.1117/1.2189292
dc.identifier.issn 0091-3286
dc.identifier.issn 1560-2303
dc.identifier.issue 4 en_US
dc.identifier.scopus 2-s2.0-33748621183
dc.identifier.scopusquality Q3
dc.identifier.uri https://doi.org/10.1117/1.2189292
dc.identifier.volume 45 en_US
dc.identifier.wos WOS:000237622200038
dc.identifier.wosquality Q4
dc.language.iso en en_US
dc.publisher Spie-soc Photo-optical instrumentation Engineers en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 3
dc.subject Autocalibration en_US
dc.subject Epipolar Geometry en_US
dc.subject Essential Matrix en_US
dc.title Experimental study on the sensitivity of autocalibration to projective camera model parameters tr_TR
dc.title Experimental Study on the Sensitivity of Autocalibration To Projective Camera Model Parameters en_US
dc.type Article en_US
dc.wos.citedbyCount 0
dspace.entity.type Publication
relation.isAuthorOfPublication 9d0ac03c-117b-485a-b923-109829e41ba1
relation.isAuthorOfPublication.latestForDiscovery 9d0ac03c-117b-485a-b923-109829e41ba1
relation.isOrgUnitOfPublication aef16c1d-5b84-42f9-9dab-8029b2b0befd
relation.isOrgUnitOfPublication.latestForDiscovery aef16c1d-5b84-42f9-9dab-8029b2b0befd

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: