Effect of electrical discharge machining on dental Y-TZP ceramic-resin bonding
dc.contributor.author | Rona, Nergiz | |
dc.contributor.author | Yenisey, Murat | |
dc.contributor.author | Küçüktürk, Gökhan | |
dc.contributor.author | Gürün, Hakan | |
dc.contributor.author | Çoğun, Can | |
dc.contributor.author | Esen, Ziya | |
dc.contributor.authorID | 3837 | tr_TR |
dc.contributor.authorID | 52373 | tr_TR |
dc.date.accessioned | 2020-03-18T08:02:13Z | |
dc.date.available | 2020-03-18T08:02:13Z | |
dc.date.issued | 2017 | |
dc.department | Çankaya Üniversitesi, Mühendislik Fakültesi, Mekatronik Mühendisliği; Mazleme Bilimi ve Mühendisliği Bölümü | en_US |
dc.description.abstract | Purpose: The study determined (i) the effects of electrical discharge machining (EDM) on the shear-bond strength (SBS) of the bond between luting resin and zirconia ceramic and (ii) zirconia ceramic's flexural strength with the three-point bending (TPB) test. Methods: Sixty 4.8 mm x 4.8 mm x 3.2 mm zirconia specimens were fabricated and divided into four groups (n = 15): SBG: sandblasted + silane, TSCG: tribochemical silica coated + silane, LTG: Er:YAG laser treated + silane, EDMG: EDM + silane. The specimens were then bonded to a composite block with a dual-cure resin cement and thermal cycled (6000 times) prior to SBS testing. The SBS tests were performed in a universal testing machine. The SBS values were statistically analyzed using ANOVA and Tukey's test. To determine flexural strength, sixty zirconia specimens were prepared and assigned to the same groups (n = 15) mentioned earlier. After surface treatment TPB tests were performed in a universal testing machine (ISO 6872). The flexural strength values were statistically analyzed using ANOVA and Tukey's test (a = 0.05). Results: The bond strengths for the four test groups (mean SD; MPa) were as follows: SBG (Control), 12.73 +/- 3.41, TSCG, 14.99 +/- 3.14, LTG, 7.93 +/- 2.07, EDMG, 17.05 +/- 2.71. The bond strength of the EDMG was significantly higher than those of the SBG and LTG (p < 0.01). The average flexural strength values for the groups SBG (Control), TSCG, LTG and EDMG were 809.47, 800.47, 679.19 and 695.71 MPa, respectively (p > 0.05). Conclusions: The EDM process improved the SBS. In addition, there was no significant adverse effect of EDM on the flexural strength of zirconia. | en_US |
dc.description.publishedMonth | 4 | |
dc.identifier.citation | Rona, Nergiz...et.al. (2017). "Effect of electrical discharge machining on dental Y-TZP ceramic-resin bonding", Journal Of Prosthodontic Research, Vol.61, No.2, pp.158-167. | en_US |
dc.identifier.doi | 10.1016/j.jpor.2016.07.006 | |
dc.identifier.endpage | 167 | en_US |
dc.identifier.issn | 1883-1958 | |
dc.identifier.issue | 2 | en_US |
dc.identifier.startpage | 158 | en_US |
dc.identifier.uri | http://hdl.handle.net/20.500.12416/2664 | |
dc.identifier.volume | 61 | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier Ireland LTD | en_US |
dc.relation.ispartof | Journal Of Prosthodontic Research | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Zirconia Ceramic | en_US |
dc.subject | Electrical Discharge Machining | en_US |
dc.subject | Bonding Strength | en_US |
dc.subject | Flexural Strength | en_US |
dc.subject | Graphite Powder | en_US |
dc.title | Effect of electrical discharge machining on dental Y-TZP ceramic-resin bonding | tr_TR |
dc.title | Effect of Electrical Discharge Machining on Dental Y-Tzp Ceramic-Resin Bonding | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication |
Files
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: