Çankaya GCRIS Standart veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Investigation of strengthened low slenderness RC column by using textile reinforced mortar strip under axial load

dc.contributor.authorMercimek, Ömer
dc.contributor.authorGhoroubi, Rahim
dc.contributor.authorÖzdemir, Anıl
dc.contributor.authorAnil, Özgür
dc.contributor.authorErbaş, Yaşar
dc.date.accessioned2024-03-19T12:47:28Z
dc.date.available2024-03-19T12:47:28Z
dc.date.issued2022
dc.departmentÇankaya Üniversitesi, Mühendislik Fakültesi, İnşaat Mühendisliği Bölümüen_US
dc.description.abstractAn experimental and numerical study was conducted to improve the critical performance of low slenderness reinforced concrete columns, such as ultimate load capacity, initial stiffness, and energy dissipation capacity, using Textile-Reinforced Mortar (TRM) strip. A total of 17 reinforced concrete columns were fabricated and tested under uni-axial compression. The effect of carbon textile type, strip width and distance, usage of carbon fiber reinforced polymer (CFRP) fan type anchors was investigated. The experimental part of the study indicated that the ultimate load capacities of reinforced concrete columns strengthened with TRM strips was increased to 1.19–1.78 times. Their initial stiffness increased to 1.01–1.99 times, and energy dissipation capacity values increased to 1.22 and 2.09 times. In addition, simulation models for the experimental specimens were created with the ABAQUS finite element software. Then the results of analyses and the experimental outputs were compared together and interpreted. Finally, using the verified FEM model, a parametric numerical study was carried out to determine the effect of the increase in the concrete compressive strength of the column on the performance of the specimens examined within the scope of the study. According to the main findings of this study, it was demonstrated that the application of the proposed TRM strips for strengthening reinforced concrete columns was a successful method.en_US
dc.description.publishedMonth5
dc.identifier.citationMercimek, Ömer;...et.al. (2022). "Investigation of strengthened low slenderness RC column by using textile reinforced mortar strip under axial load", Engineering Structures, Vol.259.en_US
dc.identifier.doi10.1016/j.engstruct.2022.114191
dc.identifier.issn1410296
dc.identifier.urihttp://hdl.handle.net/20.500.12416/7636
dc.identifier.volume259en_US
dc.language.isoenen_US
dc.relation.ispartofEngineering Structuresen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAnchoren_US
dc.subjectAxial Loaden_US
dc.subjectRC Columnen_US
dc.subjectStrengtheningen_US
dc.subjectTRMen_US
dc.titleInvestigation of strengthened low slenderness RC column by using textile reinforced mortar strip under axial loadtr_TR
dc.titleInvestigation of Strengthened Low Slenderness Rc Column by Using Textile Reinforced Mortar Strip Under Axial Loaden_US
dc.typeArticleen_US
dspace.entity.typePublication

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: