Çankaya GCRIS Standart veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Experimental investigation of damaged square short RC columns with low slenderness retrofitted by CFRP strips under axial load

dc.contributor.authorGhoroubi, Rahim
dc.contributor.authorMercimek, Ömer
dc.contributor.authorÖzdemir, Anıl
dc.contributor.authorAnıl, Özgür
dc.contributor.authorID30604tr_TR
dc.date.accessioned2021-06-16T10:25:58Z
dc.date.available2021-06-16T10:25:58Z
dc.date.issued2020
dc.departmentÇankaya Üniversitesi, Mühendislik Fakültesi, İnşaat Mühendisliği Bölümüen_US
dc.description.abstractThe aim of this study is to develop the retrofitting details, which will increase axial ultimate load capacity, stiffness, displacement ductility ratios, and energy dissipation capacities of short reinforced concrete (RC) low slenderness columns to avoid adverse effects on earthquake performance. The main variables examined in the experimental study are the Carbon Reinforced Fiber Polymer (CFRP) strip width used for retrofitting, the distance between CFRP strips, the use of the anchor at the overlap zone in the CFRP strips, and the placement of the CFRP strips horizontally or vertically to the column axis. For these purposes, eleven square short RC columns with a dimension of 150x150x500 mm (with low slenderness ratio: lambda = 11.5) were produced. The columns were damaged up to 50% of their axial load carrying capacity, then retrofitted with CFRP strips in different ways. The short RC columns with low slenderness ratio were tested under monotonic axial loading until they failure. By obtaining the axial load-displacement graphs of the test specimens, the ultimate axial load capacity, initial stiffness value, displacement-ductility ratios, and energy dissipation capacities are calculated and interpreted. It has been found that the most successful retrofitting detail is obtained when CFRP strips are placed perpendicular to the column axis, and CFRP fan-type anchors are used in the strip overlap region.en_US
dc.description.publishedMonth12
dc.identifier.citationGhoroubi, Rahim...at all (2020). "Experimental investigation of damaged square short RC columns with low slenderness retrofitted by CFRP strips under axial load", Structures, Vol. 28, pp. 170-180.en_US
dc.identifier.doi10.1016/j.istruc.2020.08.068
dc.identifier.endpage180en_US
dc.identifier.issn2352-0124
dc.identifier.startpage170en_US
dc.identifier.urihttp://hdl.handle.net/20.500.12416/4805
dc.language.isoenen_US
dc.relation.ispartofStructuresen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectRC Short Columnen_US
dc.subjectCFRPen_US
dc.subjectRetrofittingen_US
dc.subjectAxial Loaden_US
dc.subjectDuctility and Energy Dissipationen_US
dc.titleExperimental investigation of damaged square short RC columns with low slenderness retrofitted by CFRP strips under axial loadtr_TR
dc.titleExperimental Investigation of Damaged Square Short Rc Columns With Low Slenderness Retrofitted by Cfrp Strips Under Axial Loaden_US
dc.typeArticleen_US
dspace.entity.typePublication

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: