Thermal, Hydraulic, Exergitic and Economic Evaluation of a Flat Tube Heat Exchanger Equipped With a Plain and Modified Conical Turbulator
No Thumbnail Available
Date
2021
Journal Title
Journal ISSN
Volume Title
Publisher
Elsevier
Open Access Color
GOLD
Green Open Access
No
OpenAIRE Downloads
OpenAIRE Views
Publicly Funded
No
Abstract
Increasing use of fossil fuels has led to serious consequences on the environment including global warming, pollution, and increased costs of heating systems. This indicates the importance of improving the efficiency of devices used in heating and air conditioning systems such as heat exchangers. In this study, it was tried to enhance the performance of the heat exchanger by simultaneous use of a flat tube as a central tube of the heat exchanger and dual conic turbulator. In addition to plain conical turbulator, the influence of the conical turbulator with aerodynamic geometry was investigated on the heat transfer and pressure drop. Finally, economic evaluation of the studied cases was done based on the thermal performance enhancement factor (TEF) and the net profit of unit transferred heat load (eta(p)). Tests were conducted in the hot water flow rate ranging 0.033-0.0678 L/s while cold water flow rate was kept constant at 0.166 L/s. The results indicated that the heat transfers and exergy loss of the flat tube heat exchanger with a dual modified conical turbulator was up to 33% and 30% higher than the plain tube heat exchanger, respectively. Also, a heat exchanger with a modified dual turbulator with convergent embellishment (case B) selected as the economic case and has the highest TEF and eta(p). It was revealed that the application of enhanced conical turbulator would lead in the increment of eta(p) up to 1.26 times.
Description
Mahariq, Ibrahim/0000-0002-7222-3014; Marzouki, Riadh/0000-0002-2502-2164; Ayed, Hamdi/0000-0001-6108-5093
Keywords
Double Tube Heat Exchanger, Flat Tube, Modified Conical Turbulator, Heat Transfer, Pressure Drop, Flat tube, Modified conical turbulator, Double tube heat exchanger, Heat transfer, TA1-2040, Pressure drop, Engineering (General). Civil engineering (General)
Turkish CoHE Thesis Center URL
Fields of Science
0202 electrical engineering, electronic engineering, information engineering, 02 engineering and technology
Citation
Chen, Heng...et al. (2021). "Thermal, hydraulic, exergitic and economic evaluation of a flat tube heat exchanger equipped with a plain and modified conical turbulator", Case Studies in Thermal Engineering, Vol. 28.
WoS Q
Q1
Scopus Q
Q1

OpenCitations Citation Count
12
Source
Case Studies in Thermal Engineering
Volume
28
Issue
Start Page
101587
End Page
PlumX Metrics
Citations
CrossRef : 13
Scopus : 16
Captures
Mendeley Readers : 13
Google Scholar™

OpenAlex FWCI
1.1721651
Sustainable Development Goals
3
GOOD HEALTH AND WELL-BEING

9
INDUSTRY, INNOVATION AND INFRASTRUCTURE

11
SUSTAINABLE CITIES AND COMMUNITIES

12