Çankaya GCRIS Standart veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Fragility of Shear Wall Buildings with Torsional Irregularity

dc.contributor.author Akansel, Vesile Hatun
dc.contributor.author Yakut, Ahmet
dc.contributor.author Gülkan, Polat
dc.contributor.authorID 5743 tr_TR
dc.contributor.other İnşaat Mühendisliği
dc.date.accessioned 2024-03-18T11:47:31Z
dc.date.available 2024-03-18T11:47:31Z
dc.date.issued 2012
dc.department Çankaya Üniversitesi, Mühendislik Fakültesi, İnşaat Mühendisliği Bölümü en_US
dc.description.abstract Fragility curves are useful for damage assessment of structures. There are many criteria that affect the reliability of fragility curves such as transitional damage states, plan irregularity and different measures of seismic intensity. Determination of fragility of a shear wall structure is important, especially for installations that have torsional irregularity. In this study fragility curves of a shear wall building with torsional irregularity have been obtained. This building was subjected to synthetic earthquake motions on the AZALEE shaking table under the coordination of CEA (Commissariat à l’Energie Atomique) and Electricité de France (EDF) in Saclay, Paris under the scope of the SMART program. Maximum inter-story drift values have been used as the damage indicator to obtain the fragility curves and different seismic intensity measures such as PGA, PGV, PGD and CAV have been used. Thirty bi-directional horizontal ground motions have been applied for the time history analyses. These synthetic acceleration sets applied to the structure have different amplitudes in the range of 0.1 to 1 g. Micro modeling approach has been used to obtain reasonably accurate and consistent results with experiments. ANSYS finite element software has been used for the response history analyses. Fragility curves of shear wall building have been calculated according to pre-established damage indicators. The limits are light, controlled and extended damage indicators. These curves are compared with those of the HAZUS damage states for correlation. en_US
dc.identifier.citation Akansel, Vesile Hatun; Yakut, Ahmet; Gülkan, Polat. "Fragility of Shear Wall Buildings with Torsional Irregularity", 15 WCEE, 2012. en_US
dc.identifier.uri https://hdl.handle.net/20.500.12416/7599
dc.institutionauthor Gülkan, Hakkı Polat
dc.language.iso en en_US
dc.relation.ispartof 15 WCEE en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Shear Wall Building en_US
dc.subject Fragility en_US
dc.subject Torsion en_US
dc.subject Micro- Modeling en_US
dc.title Fragility of Shear Wall Buildings with Torsional Irregularity tr_TR
dc.title Fragility of Shear Wall Buildings With Torsional Irregularity en_US
dc.type Conference Object en_US
dspace.entity.type Publication
relation.isAuthorOfPublication d44435e7-f1c4-4fd5-8164-7b87924e2de4
relation.isAuthorOfPublication.latestForDiscovery d44435e7-f1c4-4fd5-8164-7b87924e2de4
relation.isOrgUnitOfPublication 77a9f192-0d56-4f8e-adf2-a1c91a7124c9
relation.isOrgUnitOfPublication.latestForDiscovery 77a9f192-0d56-4f8e-adf2-a1c91a7124c9

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: