Bilgilendirme: Kurulum ve veri kapsamındaki çalışmalar devam etmektedir. Göstereceğiniz anlayış için teşekkür ederiz.
 

Laser Ablation Device with a Closed-Loop Control System

Loading...
Publication Logo

Date

2025

Journal Title

Journal ISSN

Volume Title

Publisher

Optica Publishing Group

Open Access Color

Green Open Access

No

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Average
Influence
Average
Popularity
Average

Research Projects

Journal Issue

Abstract

A laser ablation device with real-time beam power control is designed and implemented. This platform regulates the intensity of the laser beam by continuously measuring its intensity distribution. The quality of the ablation process is optimized through a closed-loop control system that uses a rule-based decision-making approach. The controller generates a starting signal for both the laser power and the motors based on the estimated quality of the ablation. The effects of laser power and light intensity on the formation of microchannels in polymethylmethacrylate material were investigated using the laser beam. The quality of the ablation geometry was assessed through image processing and inspection under a scanning electron microscope. The generated microchannels were analyzed in terms of roughness and residual thermal stress. A comparison of the experimental results with theoretical calculations and simulations revealed that the closed-loop control of laser beam power is effective for material etching and for creating smoother channel profiles. (c) 2025 Optica Publishing Group. All rights, including for text and data mining (TDM), Artificial Intelligence (AI) training, and similar technologies, are reserved.

Description

Keywords

Fields of Science

Citation

WoS Q

Q3

Scopus Q

Q3
OpenCitations Logo
OpenCitations Citation Count
N/A

Source

Applied Optics

Volume

64

Issue

30

Start Page

9121

End Page

9128
PlumX Metrics
Captures

Mendeley Readers : 1

Page Views

6

checked on Feb 24, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
0.0

Sustainable Development Goals

SDG data could not be loaded because of an error. Please refresh the page or try again later.