Detection of Lead and Cadmium Ions by Voltammetry Using Antimony Impregnated Activated Carbon
| dc.contributor.author | Farooqi, Muhammad Omer | |
| dc.contributor.author | Baleanu, Dumitru | |
| dc.contributor.author | Taimoor, Aqeel Ahmad | |
| dc.contributor.author | Al-Shahrani, Saad | |
| dc.contributor.author | Baleanu, Dumitru | |
| dc.contributor.author | Rather, Sami Ullah | |
| dc.contributor.other | Matematik | |
| dc.date.accessioned | 2025-09-23T12:47:51Z | |
| dc.date.available | 2025-09-23T12:47:51Z | |
| dc.date.issued | 2015 | |
| dc.description | Taimoor, Aqeel/0000-0001-9606-5295 | en_US |
| dc.description.abstract | This work deals with antimony-impregnated activated carbon electrode for the detection of heavy metal ions. Activated carbon is employed to enhance the surface area of the working electrode. Square-wave Anodic Stripping Voltammetry is performed to analyze the electrolytic solution. The peak currents for cadmium and lead are 29.2 and 49.44 mu A respectively, in 100 mu g/L of cadmium and lead solution, which are considerably higher when equated with the previous reported values. Results also indicate that antimony-impregnated activated carbon is better when compared with the ratio of antimony amount to minimum detection limit. | en_US |
| dc.identifier.citation | Farooqi, M.O...et al. (2015). Detection of lead and cadmium ions by voltammetry using antimony impregnated activated carbon. Revista De Chimie, 66(4), 499-502. | en_US |
| dc.identifier.issn | 0034-7752 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12416/15210 | |
| dc.language.iso | en | en_US |
| dc.publisher | Chiminform Data S A | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | Anodic Stripping Voltammetry | en_US |
| dc.subject | Working Electrode | en_US |
| dc.subject | Antimony | en_US |
| dc.subject | Impregnation | en_US |
| dc.title | Detection of Lead and Cadmium Ions by Voltammetry Using Antimony Impregnated Activated Carbon | en_US |
| dc.title | Detection of lead and cadmium ions by voltammetry using antimony impregnated activated carbon | tr_TR |
| dc.type | Article | en_US |
| dspace.entity.type | Publication | |
| gdc.author.id | Taimoor, Aqeel/0000-0001-9606-5295 | |
| gdc.author.wosid | Rather, Sami-Ullah/J-9766-2013 | |
| gdc.author.wosid | Baleanu, Dumitru/B-9936-2012 | |
| gdc.author.wosid | Alshahrani, Saad/Agj-9533-2022 | |
| gdc.author.wosid | Taimoor, Aqeel/K-2661-2013 | |
| gdc.coar.access | metadata only access | |
| gdc.coar.type | text::journal::journal article | |
| gdc.description.department | Çankaya University | en_US |
| gdc.description.departmenttemp | [Farooqi, Muhammad Omer; Taimoor, Aqeel Ahmad; Al-Shahrani, Saad; Rather, Sami Ullah] King Abdulaziz Univ, Jeddah 21589, Saudi Arabia; [Baleanu, Dumitru] Cankaya Univ, Fac Arts & Sci, Dept Math & Comp Sci, TR-06530 Ankara, Turkey; [Baleanu, Dumitru] Inst Os Space Sci Magurele, RO-077125 Bucharest, Romania | en_US |
| gdc.description.endpage | 502 | en_US |
| gdc.description.issue | 4 | en_US |
| gdc.description.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| gdc.description.startpage | 499 | en_US |
| gdc.description.volume | 66 | en_US |
| gdc.description.woscitationindex | Science Citation Index Expanded | |
| gdc.identifier.wos | WOS:000354914500013 | |
| gdc.publishedmonth | 4 | |
| gdc.virtual.author | Baleanu, Dumitru | |
| gdc.wos.citedcount | 5 | |
| relation.isAuthorOfPublication | f4fffe56-21da-4879-94f9-c55e12e4ff62 | |
| relation.isAuthorOfPublication.latestForDiscovery | f4fffe56-21da-4879-94f9-c55e12e4ff62 | |
| relation.isOrgUnitOfPublication | 26a93bcf-09b3-4631-937a-fe838199f6a5 | |
| relation.isOrgUnitOfPublication | 28fb8edb-0579-4584-a2d4-f5064116924a | |
| relation.isOrgUnitOfPublication | 0b9123e4-4136-493b-9ffd-be856af2cdb1 | |
| relation.isOrgUnitOfPublication.latestForDiscovery | 26a93bcf-09b3-4631-937a-fe838199f6a5 |