    A Metaverse-Based Fully Immersive Training for Temporomandibular Joint: A Pilot Study
    (Wiley, 2026) Ozcelik, Erol; Ekici, Saliha Zerdali; Basmaci, Fulya; Cagiltay, Nergiz Ercil; Kilicarslan, Mehmet Ali
    Objective Understanding the temporomandibular joint (TMJ) can be challenging with conventional methods, as its complex anatomy, comprising the articular disc, mandibular condyle, and temporal bone, requires detailed visualisation. Traditional approaches like textbooks and static images often fall short, whereas modern tools such as 3D modelling and virtual reality (VR) offer more effective alternatives. Metaverse technology further enhances this by creating interactive, immersive and collaborative learning environments that simulate real-world experiences. While VR is increasingly used in dental education, research on fully immersive metaverse-based learning remains limited.Methods In this pilot study, a custom metaverse environment was developed to teach TMJ concepts. Then, the effectiveness of conventional and metaverse-based teaching methods in improving dental students' understanding of the TMJ was evaluated experimentally. A randomised trial was conducted with 120 first-year dental students, divided into three groups: classical lecturing, metaverse-based training and a combination of both.Results Findings indicate that students in the metaverse and combined groups outperformed those in the classical lecturing group, with no significant difference between the two metaverse-involved groups.Conclusions This suggests that for highly complex anatomical structures like the TMJ, metaverse-based training alone may be sufficient, eliminating the need for additional traditional instruction. The study highlights the metaverse's potential to enhance dental education by providing a fully 3D, interactive learning experience.
  • Article
    Comparison of the Unmodified Rytov Method and the Modified Rytov Method in Obtaining Scintillations in Various Strongly Turbulent Media
    (Optica Publishing Group (Formerly OSA), 2026) Baykal, Y.
    The scintillation index as evaluated by the unmodified (classical) Rytov method solution for weak turbulence and evaluated by the modified or the extended Rytov method solution for strong turbulence is compared in different turbulent media, such as non-Kolmogorov atmospheric, non-Kolmogorov jet engine exhaust, marine atmospheric, and oceanic turbulences. When the scintillations are evaluated against the turbulence strength for various non-Kolmogorov power law and source sizes, the distinction between the modified Rytov and the unmodified Rytov method solutions, as the strength of turbulence increases, is clearly observed in all the turbulent media. This distinction is emphasized when the comparison is made at larger power law and source sizes. The results in this paper will be helpful in optical wireless communication system performance evaluations. © 2025 Optica Publishing Group.
  • Article
    Field Correlations of a Gaussian Vortex Laser Beam in Vertical Turbulent Oceanic Links
    (Optica Publishing Group (Formerly OSA), 2026) Gerçekcioǧlu, H.; Baykal, Y.
    Utilizing the extended Huygens–Fresnel principle, field correlations of a Gaussian vortex beam propagating in the vertical turbulent oceanic link are examined analytically and evaluated by simulation in the Atlantic Ocean at low- and mid-latitude and high-latitude summer. Our formulation is based on the coherence length of a spherical wave operating at the depth range between 3000 and 3500 m. Variations in the rate of dissipation of turbulent kinetic energy per unit mass of fluid ε, the rate of dissipation of the mean-squared temperature χT, and the ratio of temperature to salinity contributions to the refractive index spectrum ω are taken into account at these depths in the underwater turbulent medium. The field correlation obtained using the coherence length found with the help of the depth-dependent power spectrum is expressed in detail. When the topological charge is selected considering the source size and propagation distance, it is seen that the normalized field correlation of the Gaussian vortex beam gives better results as compared to Gaussian beams. © 2025 Optica Publishing Group. All rights, including for text and data mining (TDM), Artificial Intelligence (AI) training, and similar technologies, are reserved.
  • Article
    Beam Shaping on a Fluorescent On-Chip Imaging System
    (IOP Publishing Ltd, 2026) Arpali, Caglar; Arpali, Serap Altay
    The fluorescent on-chip imaging system differs from a conventional fluorescent microscope in terms of the imaging method because the sample is directly placed on the imaging sensor (i.e., charge-coupled device (CCD)). While this imaging modality presents several advantages, including a wide field of view and rapid scanning speed, it can be difficult to detect certain particles in dense and scattering environments, such as whole blood and tissue. These difficulties lead to a decreased signal-to-noise ratio (SNR) in the captured images, influenced by both the medium's light-transmitting capability and the excitation techniques used. In this paper, we quantitatively examine the effect of beam shaping techniques on a fluorescent on-chip imaging system from the SNR perspective. An experimental comparison is conducted between a Gaussian beam and plane-wave illumination generated by a novel phase modulation schema using our developed imaging platform. The results indicate that the Gaussian beam produces higher SNR images than plane waves when detecting fluorescent particles in a microchannel. Gaussian beam's higher energy confinement ability enhances the image quality of on-chip fluorescent imaging systems, particularly involving scattering-like medium limitations.
  • Article
    Field Correlations in Jet Engine Exhaust Turbulence
    (Optica Publishing Group (Formerly OSA), 2026) Baykal, Y.
    Field correlations of collimated Gaussian beams are formulated and examined in jet engine exhaust turbulence. Variations of the field correlations are evaluated against the changes in the parameters of the wireless optical communication link and the jet engine exhaust turbulence. It is found that for all the link and turbulence parameters of interest, as the diagonal distance at the receiver plane increases, the field correlation decreases. Also, at the same diagonal distance from the receiver plane, field correlations tend to become smaller as the receiver points are at a larger distance from the receiver origin, at a smaller source size, wavelength, and inner scale values of jet engine exhaust turbulence. On the other hand, field correlations have a tendency to attain larger values at smaller link length, structure constant, amplitude coefficient for the additional high frequency spectrum area, outer scale of inhomogeneity, and the outer scale values of jet engine exhaust turbulence. © 2025 Optica Publishing Group. All rights, including for text and data mining (TDM), Artificial Intelligence (AI) training, and similar technologies, are reserved.
  • Article
    Laser Ablation Device with a Closed-Loop Control System
    (Optica Publishing Group, 2025) Beldek, Ulas; Erdogan, Kubra; Arpali, Caglar; Baykal, Yahya
    A laser ablation device with real-time beam power control is designed and implemented. This platform regulates the intensity of the laser beam by continuously measuring its intensity distribution. The quality of the ablation process is optimized through a closed-loop control system that uses a rule-based decision-making approach. The controller generates a starting signal for both the laser power and the motors based on the estimated quality of the ablation. The effects of laser power and light intensity on the formation of microchannels in polymethylmethacrylate material were investigated using the laser beam. The quality of the ablation geometry was assessed through image processing and inspection under a scanning electron microscope. The generated microchannels were analyzed in terms of roughness and residual thermal stress. A comparison of the experimental results with theoretical calculations and simulations revealed that the closed-loop control of laser beam power is effective for material etching and for creating smoother channel profiles. (c) 2025 Optica Publishing Group. All rights, including for text and data mining (TDM), Artificial Intelligence (AI) training, and similar technologies, are reserved.
  • Article
    Citation - WoS: 16
    Citation - Scopus: 16
    Comparative Application of Wavelet Approaches To Absorption and Ratio Spectra for the Simultaneous Determination of Diminazene Aceturate and Phenazone in Veterinary Granules for Injection
    (Govi-verlag Pharmazeutischer verlag Gmbh, 2005) Dinç, E; Baleanu, Dumitru; Kanbur, M; Baleanu, D; Matematik
    A comparison of two wavelet approaches, Daubechies and reverse Biorthogonal, is described for the quantitative resolution of a binary mixture of diminazene aceturate (DIMA) and phenazone (PHE) in veterinary granules for injection without any chemical separation. These two approaches were specified as db4 (a = 180) and rbior3.7 (a = 125) respectively, after testing the signal analysis parameters for the overlapping absorption spectra and ratio spectra. In the first step db4 (a = 180) was applied to the original absorbance data vector of DIMA and PHE. In the second step rbio3.7 (a = 125) was applied to the ratio spectra data vectors of DIMA using the divisor PHE. The same approach was also subjected to the ratio spectra of PHE using the divisor DIMA. The db4 (a = 180) and rbior3.7 (a = 125) calibration graphs were constructed using the transformation values obtained in the wavelet domain. In the method validation, the wavelet calibration functions were tested using synthetic mixtures and the standard addition technique. The simultaneous quantitative analysis of DIMA and PHE in the commercial veterinary preparation was achieved by the elaborated methods. The assay results were compared with each other and good agreement was observed.
  • Article
    Citation - WoS: 8
    Citation - Scopus: 8
    Dimensions of Agitation Based on the Cohen-Mansfield Agitation Inventory in Patients With Dementia
    (Turkiye Sinir ve Ruh Sagligi dernegi, 2015) Altunoz, Umut; Baştuğ, Gülbahar; Ozel Kizil, Erguvan Tugba; Kirici, Sevinc; Bastug, Gulbahar; Bicer Kanat, Bilgen; Sakarya, Aysegul; Turan, Engin; Kanat Biçer, Bilgen; Psikoloji
    Objective: The aim of this study was to investigate the dimensions of agitation in dementia patients using the Turkish version of the Cohen-Mansfield Agitation Inventory (CMAI-T). Materials and Method: The study included 100 patients diagnosed as dementia, according to the DSM-IV-TR. The CMAI-T was administered to the patients' caregivers via face-to-face interviews. The Standardized Mini Mental State Examination (SMMSE) was used to assess cognitive functions. The severity of depression and the functional state of the patients were assessed using the Cornell Scale for Depression in Dementia (CSDD) and the Functional Activities Questionnaire (FAQ). Principal component analysis and varimax rotation were used to determine the factor structure of the CMAI-T. Results: Factor analysis of the CMAI-T indicated a 3-factor structure: physically aggressive agitation, verbal agitation, and physically non-aggressive agitation. In 92% of the patients there >= 1 was agitation behavior during the previous 2 weeks. The CMAI-T total and factor scores were negatively correlated with the SMMSE scores, and positively correlated with the CSDD and the FAQ scores. Conclusions: The CMAI-T yielded 3 factors (physically aggressive agitation, verbal agitation, and physically non-aggressive agitation), which indicated the scale had construct validity Agitation behaviors were associated with cognitive dysfunction, symptoms of depression and general level of functioning. Additional research is necessary to identify the predictors of these dimensions in different dementia samples, and to determine the efficacy of therapeutic interventions.
  • Article
    Citation - WoS: 13
    Citation - Scopus: 14
    Continuous Wavelet Transformation Applied To the Simultaneous Quantitative Analysis of Two-Component Mixtures
    (Govi-verlag Pharmazeutischer verlag Gmbh, 2004) Dinç, E; Baleanu, Dumitru; Baleanu, D; Üstündag, Ö; Aboul-Enein, HY; Matematik
    In this paper we developed a graphical method based on Haar (HA) and Mexican (MEX) one-dimensional continuous wavelet transforms and we applied it to a mixture of hydrochlorothiazide (HCT) and spironolactone (SP) in the presence of strongly overlapping signals. Keeping in mind to obtain an appropriately transformed spectrum, we tested several values of the scaling parameter a and the point number of the analysed spectrum in the concentration range of 2-22 mug/ml for both active compounds. The optimal values of the scale parameters and the corresponding frequencies were found to be a = 32 and 0.031 for HA and a = 30 and 0.008 for MEX corresponding to 400 points. HA and MEX methods based on a zero crossing technique were applied to the analysed signal and their regression lines at the selected points were obtained. The validation of the above methods was carried out by analysing different synthetic mixtures containing HCT and SP. MATLAB 6.5. Software was used for one-dimensional wavelet analysis and the basic concepts about wavelet method were briefly explained. The method developed in this paper is rapid, easy to apply, inexpensive and is suitable for analysing the overlapping signals of compounds in their mixtures without any chemical pre-treatment.
  • Article
    Citation - WoS: 8
    Citation - Scopus: 8
    Continuous Wavelet Transform Applied To the Quantitative Analysis of a Binary Mixture
    (Revista Chimie Srl, 2009) Dinc, Erdal; Baleanu, Dumitru; Baleanu, Dumitru; Üstündag, Ö; Aboul-Enein, HY; Matematik
    Signal processing methods, continuous wavelet transform (CWT) methods, were proposed for the simultaneous spectral determination of ampicillin sodium (AS) and sulbactam sodium (SS) in their synthetic binary mixtures and pharmaceutical preparations. Firstly, the ratio spectra were obtained by dividing the absorption spectra of a pure compound and its binary mixture by a standard spectrum of one of the compounds in binary mixture. Secondly, the ratio spectra of AS, SS and their samples were processed by the Mexican hat-CWT and Symtles3-CWT (MEX-CWT and SYM3-CWT, respectively). hi this application, the MEX and SYM3 among wavelet families were found to be optimal to obtain the highest spectral recoveries. Calibration graphs of AS and SS in the linear concentration range of 10-70 mu g/mL and 10-55 mu g/mL were obtained by measuring the amplitudes of the transformed ratio signals, respectively. Percent mean recoveries obtained by application of the CWT methods to the synthetic mixtures were found between 99.1 % and 103.6 %. Both SYM3-CWT and MEX-CWT methods were applied to the real samples containing two active compounds and successful results were obtained.