WoS İndeksli Yayınlar Koleksiyonu
Permanent URI for this collectionhttps://hdl.handle.net/20.500.12416/8653
Browse
4 results
Search Results
Article Citation - WoS: 15Citation - Scopus: 17Scintillation Analysis of Hypergeometric Gaussian Beam Via Phase Screen Method(Elsevier, 2013) Eyyuboglu, Halil T.We give a scintillation treatment of hypergeometric Gaussian beams via the use of random phase screens. In particular, we analyse the on-axis, point-like and aperture averaged power scintillation characteristics of this beam that cannot be undertaken easily by analytic means. Within the range of examined source and propagation parameters, our evaluations show that there will be less scintillation, with increasing hollowness at small source sizes and zero topological charge. At larger source sizes or topological charges, this is reversed and decreasing hollowness will reduce scintillation. More or less the same trend is observed for aperture averaging such that at small source sizes and zero topological charge, increased hollowness will result in lower scintillation. At larger source size and topological charges, there will be a transition from the case of smaller values of hollowness giving rise to less scintillation at smaller aperture openings to the case of larger values of hollowness giving rise to less scintillation at larger aperture openings. In general nonzero topological charges will produces more scintillations, both in on-axis and aperture averaged cases. (C) 2013 Elsevier B.V. All rights reserved.Article Citation - WoS: 13Citation - Scopus: 13Per Unit Received Power Apertured Averaged Scintillation of Partially Coherent Sinusoidal and Hyperbolic Gaussian Beams(Elsevier Sci Ltd, 2015) Eyyuboglu, Halil T.; Eyyuboʇlu, Halil T.We evaluate the per unit power received power aperture averaged scintillation performance of fully and partially coherent sinusoidal and hyperbolic Gaussian beams. Our analysis includes fundamental Gaussian, cosh Gaussian, cos Gaussian and annular Gaussian beams. The method is based on our earlier introduced semi-analytic approach. Scintillation performance is measured upon dividing the aperture averaged scintillation by the received power. Assessment is made both for aperture sizes that are adjusted separately for full and partially coherent beams to capture 10% and 20% of the equal source power and also for fixed aperture sizes. This way, the scintillation performance of the different beams in question is compared. From this comparison, we find that partially coherent beams have lower scintillation than the fully coherent ones, when adjustable aperture size is used. But upon switching to fixed aperture size, the reverse happens and coherent beams become more advantageous. In all cases of comparison, small source sized annular Gaussian beam and large source sized Gaussian beam seem to offer the lowest scintillation when aperture size is adjusted to capture 20% of the equal source power. (C) 2015 Elsevier Ltd. All rights reserved.Article Citation - WoS: 40Citation - Scopus: 45Scintillation Behavior of Airy Beam(Elsevier Sci Ltd, 2013) Eyyuboglu, Halil T.We make an analysis on scintillation behavior of Airy beam using the Rytov method. To this end, scintillation index is formulated for a single receiver coordinate location. Area scintillation expressions are also derived. At peaks of receiver intensity, Airy beam is found to offer quite less scintillation at width values of around 1.6 cm. Furthermore, smaller values of the exponential truncation factor are also seen to cause less scintillation. When compared to Gaussian beam, on equal source and received power basis, it is observed that Airy beam will generally have less area scintillation. (C) 2012 Elsevier Ltd. All rights reserved.Article Citation - WoS: 30Citation - Scopus: 31Estimation of Aperture Averaged Scintillations in Weak Turbulence Regime for Annular, Sinusoidal and Hyperbolic Gaussian Beams Using Random Phase Screen(Elsevier Sci Ltd, 2013) Eyyuboglu, Halil T.Using the random phase screen method, aperture averaged scintillations for annular, sinusoidal and hyperbolic Gaussian beams are estimated. Prior to this estimation, the designed random phase screen setup is tested against the known results of the existing literature from the aspects of receiver intensity distribution, point-like scintillation index and aperture averaged scintillation of spherical and Gaussian beam waves. Having obtained satisfactory results, we then proceed to estimate aperture averaged scintillations for annular, sinusoidal and hyperbolic Gaussian beams. Our findings indicate that at a fixed aperture radius of 5 cm, sine Gaussian beam exhibits the highest scintillation, annular Gaussian beam has on the other hand has the lowest scintillations. When examined against varying aperture sizes, the scintillation ordering of beams does not change. Furthermore, although larger aperture sizes achieve substantial scintillation reductions, the rate of reductions gradually become smaller. (C) 2013 Elsevier Ltd. All rights reserved.
